2002
DOI: 10.1016/s0969-806x(02)00276-1
|View full text |Cite
|
Sign up to set email alerts
|

K-shell X-ray production cross-sections and fluorescence yields in some medium-Z elements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
12
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(13 citation statements)
references
References 26 publications
1
12
0
Order By: Relevance
“…In the last few years there has been a considerable increase in the number of experimental high precision measurements of the K shell fluorescence yields for many elements [9,10,11,12,13,14,15,16,17]. The results show several discrepancies when compared with theoretical and semi-empirical data.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the last few years there has been a considerable increase in the number of experimental high precision measurements of the K shell fluorescence yields for many elements [9,10,11,12,13,14,15,16,17]. The results show several discrepancies when compared with theoretical and semi-empirical data.…”
Section: Introductionmentioning
confidence: 99%
“…The results show several discrepancies when compared with theoretical and semi-empirical data. For Cd, for example, four experimental results have been published in this decade [11,13,14,17]. Yet, no relativistic calculation has been performed so far for this element.…”
Section: Introductionmentioning
confidence: 99%
“…The K lines for present elements separated from the Ar K lines and so, for these targets, there was no problem in evaluating the peak integral of the K X-ray lines. According to earlier methods [3][4][5][6][7][8][9][10][11][12][13][14], it is necessary to measure L X-ray production cross-sections at above and below energies from K shell binding energy. For the Si (Li) or Ge (Li) spectrometer, it is not possible to determine L X-ray line intensities for the low atomic number elements because of detector efficiency.…”
Section: Resultsmentioning
confidence: 99%
“…Recently, there were several works on L X-ray intensity ratio [2][3], K, L and M X-ray production cross-sections [4][5][6][7][8], Coster-Kronig transitions probabilities [9][10] and chemical effect [11] for many elements using EDXRF spectrometry.…”
Section: Introductionmentioning
confidence: 99%
“…These data also serve as important inputs in the XRF technique which is considered to be one of the most powerful methods for elemental analysis. In a few recent measurements (Ö zdemir et al, 2002;Durak and Ö zdemir, 2001b;Karabulut et al, 1999;Durak, 1998), it has been demonstrated that the K shell fluorescence cross sections can be calculated with an accuracy of a few percent. For the L shell, however, the scenario is far from satisfactory.…”
Section: Introductionmentioning
confidence: 99%