1996
DOI: 10.1080/00102209608935563
|View full text |Cite
|
Sign up to set email alerts
|

Jet-REMPI for the Detection of Trace Gas Compounds in Complex Gas Mixtures, a Tool for Kinetic Research and Incinerator Process Control

Abstract: Flame optimization in incinerators is achievable by feedback control via kinetic modelling and on-line monitoring. On-line monitoring for process control requires a fast, selective and sensitive analytical device. In this paper a REM PI (Resonance Enhanced Multi Photon Ionization) mass spectrometer is presented which combines high sensitivity with very low cross-sensitivity. Consequently, it should be a valuable tool for both kinetic research and for on-line investigation. The sensitivity of the instrument has… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
39
0
1

Year Published

1999
1999
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(40 citation statements)
references
References 10 publications
0
39
0
1
Order By: Relevance
“…The resonance-enhanced multiphotonionization time-of-flight mass spectrometry (REMPI-TOFMS) technique has been used for the on-line measurement of chlorobenzenes. [2][3][4][5][6][7][8][9] Zimmermann et al [2][3][4][5][6] constructed mobile instruments for on-line monitoring of polyaromatic hydrocarbons and other aromatic species in the flue gas of industrial incineration plants. also performed REMPI mass spectrometry to detect chlorinated aromatic compounds.…”
Section: Introductionmentioning
confidence: 99%
“…The resonance-enhanced multiphotonionization time-of-flight mass spectrometry (REMPI-TOFMS) technique has been used for the on-line measurement of chlorobenzenes. [2][3][4][5][6][7][8][9] Zimmermann et al [2][3][4][5][6] constructed mobile instruments for on-line monitoring of polyaromatic hydrocarbons and other aromatic species in the flue gas of industrial incineration plants. also performed REMPI mass spectrometry to detect chlorinated aromatic compounds.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, a detection limit of 12 pptV with an integration time of 10 s for 2,5-DCT has been achieved with MPLI, which is considerably lower than the value of 100 pptV reported by Oser et al [9]. In their experiments, a 10 mm 3 ionization volume and an integration time of 20 seconds was used.…”
Section: Sensitivitymentioning
confidence: 86%
“…Typical pulse durations, observed at 50% intensity, are ϳ11 ns for the tunable radiation and ϳ25 ns for the radiation emitted directly from the excimer laser. Pump and ionization laser pulses were synchronized with a four channel Stanford DG 505 (Stanford, Sunnyvale, CA) [9]. The redesigned ion source geometry allows for significant reduction of the nozzle/ skimmer distance in an orthogonal beam geometry.…”
Section: Laser Systemsmentioning
confidence: 99%
“…It should be noted in this respect that Oser et al used a skimmer for the separation of ionization and ion-acceleration regions. 11 In the proximity ionization scheme, the laser beam is proposed to be line-focused in a jet to form a disk-like ionization region, which is suitable for improving both the ionization efficiency and the mass resolution. A new type of electrode assembly is desirable to properly focus the ion spread in the disk-like volume and to avoid the introduction of neutral expanded gas into the drift region.…”
Section: Resultsmentioning
confidence: 99%
“…It should be noted that a portion of the ions is accelerated toward the chamber surface, since the potential of the chamber is 0 V. Oser and co-workers applied -2000 V to the skimmer electrode, and, under these conditions, the ions were found to be efficiently extracted into the skimmer. 11 In this case, the potential of the flight tube, unfortunately, becomes -2000 V, since the difference in the potential between the skimmer and the drift tube should be zero.…”
Section: Repeller and Ground Skimmer Electrodesmentioning
confidence: 99%