Isobaric Vapor–Liquid Equilibrium Data for Six Binary Systems: Prop-2-en-1-ol (1)–Hexan-2-ol (2), Prop-2-en-1-ol (1)–Hexan-2-one (2), Hexan-2-one (1)–Hexan-2-ol (2), Prop-2-en-1-ol (1)–4-Methyl-pentan-2-ol (2), Prop-2-en-1-ol (1)–4-Methyl-pentan-2-one (2), and 4-Methyl-pentan-2-one (1)–4-Methyl-pentan-2-ol (2) at 101.32 kPa

Abstract: In this work, isobaric vapor−liquid equilibrium (VLE) measurements were conducted for the binary systems of prop-2-en-1-ol (1)−hexan-2-ol (2), prop-2-en-1-ol (1)−hexan-2-one (2), hexan-2-one (1)−hexan-2-ol (2), prop-2-en-1-ol (1)−4-methyl-pentan-2-ol (2), prop-2-en-1-ol (1)−4-methyl-pentan-2one (2), and 4-methyl-pentan-2-one (1)−4-methyl-pentan-2-ol (2) to assist with the design of the separation process by distillation. Measurements were determined using Fischer VLE 602 equipment at 101.32 kPa. The thermodyna… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 37 publications
0
2
0
Order By: Relevance
“…VLE data were measured by using a recirculation ebulliometer (Labodest VLE 602, ILUDEST, Germany). This commercial apparatus is routinely employed to acquire isobaric VLE data under low pressure and is extensively described in our previous works , and in many other studies. , Figure depicts the experimental VLE device.…”
Section: Methodsmentioning
confidence: 99%
“…VLE data were measured by using a recirculation ebulliometer (Labodest VLE 602, ILUDEST, Germany). This commercial apparatus is routinely employed to acquire isobaric VLE data under low pressure and is extensively described in our previous works , and in many other studies. , Figure depicts the experimental VLE device.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, to improve the reliability of the column distillation unit, binary coefficients based on the UNIQUAC thermodynamic model were employed (Equation ( 2)). The binary coefficients of mixtures such as allyl/2-hexanone, allyl/2-hexanol and 2-hexanone/2-hexanol obtained via data regression of vapour-liquid equilibrium (VLE), were taken from [11]. Allyl alcohol/water, 2-hexanol/water and 2-hexanone/water binary coefficients were obtained from the Aspen Plus database.…”
Section: Solvent Recoverymentioning
confidence: 99%
“…In the first step, the DODH reaction of glycerol to allyl alcohol was performed to obtain the kinetic data required for the design of the conversion operation. Furthermore, in order to improve the reliability of the separation process, accurate binary coefficients of UNIQUAC thermodynamic model were calculated using data regression of vapour-liquid equilibrium (VLE) reported in a previous study [11]. The kinetic data from the DODH reaction and the thermodynamic data from the VLE data regression were used for the simulation process performed using the Aspen Plus software.…”
Section: Introductionmentioning
confidence: 99%
“…Isobaric vapor-liquid equilibrium measurements for pure components and mixtures were performed using a recirculation ebulliometer (Labodest VLE 602, ILUDEST, Waldbüttelbrunn, Germany) equipped with a Cottrell pump. This type of equipment is routinely employed for low-pressure VLE measurements and extensively described in the literature [32][33][34][35][36].…”
Section: Vle Measurement Equipmentmentioning