1987
DOI: 10.1021/cr00077a010
|View full text |Cite
|
Sign up to set email alerts
|

IR-laser photochemistry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
103
0
1

Year Published

1998
1998
2017
2017

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 274 publications
(107 citation statements)
references
References 87 publications
1
103
0
1
Order By: Relevance
“…High-power pulsed IR irradiation was particularly useful for studying multiphoton dissociation of small molecules. Excitation of small molecules usually requires resonant absorption of several IR photons followed by incoherent excitation (Lupo & Quack, 1987). In this case, resonant absorption is the rate-limiting step and presents a ''bottleneck'' for the IR excitation.…”
Section: Multiphoton Dissociationmentioning
confidence: 99%
“…High-power pulsed IR irradiation was particularly useful for studying multiphoton dissociation of small molecules. Excitation of small molecules usually requires resonant absorption of several IR photons followed by incoherent excitation (Lupo & Quack, 1987). In this case, resonant absorption is the rate-limiting step and presents a ''bottleneck'' for the IR excitation.…”
Section: Multiphoton Dissociationmentioning
confidence: 99%
“…Recently [29] we have employed a slit-jet supersonic expansion to simplify the spectrum of the ν 1 band around 1085 cm -1 recorded with a tunable diode laser spectrometer, resolving almost completely the K-structure of many P(J) and R(J) multiplets and so improving our earlier results [30]. Here we complete the jet-cooled high-resolution study of the region coming from 2ν 5 and ν 2 + ν 3 for both the bromine isotopologues.…”
Section: Introductionmentioning
confidence: 73%
“…As a consequence, a more reliable and accurate set of spectroscopic parameters has been obtained for 2ν 5 and ν 2 + ν 3 of both the bromine isotopologues. Furthermore, many features belonging to various hot bands have been identified, and the corresponding sets of molecular constants have been determined.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3][4] Conventionally, LC is frequently coupled with UV-Vis detection for the identification of the separated substances based on their UV-Vis absorption. However, this method is not suitable for analytes that do not absorb in the UV-Vis region.…”
Section: Introductionmentioning
confidence: 99%