2016
DOI: 10.1007/s40846-016-0117-0
|View full text |Cite
|
Sign up to set email alerts
|

Ir-192 Calibration in Air with Farmer Chamber for HDR Brachytherapy

Abstract: A comprehensive review for the in-air calibration of an Ir-192 high-dose-rate brachytherapy source in terms of air kerma strength (AKS) and reference air kerma rate (RAKR) using the Farmer chamber was conducted. The reviewed calibration methods include the National Physical Laboratory (NPL) calibration standard in the UK, the 7-distance technique with the standard calibration of the National Institute of Standards and Technology and Accredited Dosimetry Calibration Laboratory in the US, the calibration conduct… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 24 publications
0
3
0
Order By: Relevance
“…At our institute the HDR brachytherapy unit named Flexitron (Nucletron, Mallinckrodt Medical B.V., The Netherland originally from Isodose Control now known as Elekta Medical Systems) having a maximum source capacity of 12 Ci (442GBq) for Iridium-192 was installed/commissioned and was first used for patient treatment on 28.07.2011. Frequent source replacement after every 4-5 months requires for Ir-192 source due to its short half-life (73.84-74days) [16][17]. In brachytherapy the accurate execution of planned dose depends upon several factors such as properly calibrated dose measuring equipment, measurement set up, agreement between TPS and manual treatment time calculation, the methodology adopted to measure the RAKR and correct entry of source specific data into TPS.…”
Section: Methodsmentioning
confidence: 99%
“…At our institute the HDR brachytherapy unit named Flexitron (Nucletron, Mallinckrodt Medical B.V., The Netherland originally from Isodose Control now known as Elekta Medical Systems) having a maximum source capacity of 12 Ci (442GBq) for Iridium-192 was installed/commissioned and was first used for patient treatment on 28.07.2011. Frequent source replacement after every 4-5 months requires for Ir-192 source due to its short half-life (73.84-74days) [16][17]. In brachytherapy the accurate execution of planned dose depends upon several factors such as properly calibrated dose measuring equipment, measurement set up, agreement between TPS and manual treatment time calculation, the methodology adopted to measure the RAKR and correct entry of source specific data into TPS.…”
Section: Methodsmentioning
confidence: 99%
“…This test was performed by comparing scatter correction factors calculated with and without inclusion of jig scatter effects. A scatter correction without jig effects was calculated using Chang et al's empirical scatter estimate [15,16], which assumes that scatter comes from the surfaces bounding the room in which the measurement is made (walls, ceiling, floor) and therefore relies on the room dimensions to calculate the scatter correction. Scatter corrections that take jig scatter into account (along with wall, ceiling, floor and other sources of scatter in the room) were evaluated using physical measurements at several set distances from the source.…”
Section: Design and Fabrication Of 3d Printed Jigmentioning
confidence: 99%
“…Having completed the in-house evaluation of jig scatter effects described in the previous section, scatter corrections were calculated for all data sets using Chang et al's empirical scatter estimate [15,16], using dimensions for each treatment room.…”
Section: Design and Fabrication Of 3d Printed Jigmentioning
confidence: 99%
“…In this calibration technique known as In-air measurement technique, we need a strategy for adjusting a 'high-vitality' photon source utilizing an in-air alignment system [15]. This technique is not very useful for 125 I or 103 Pd because of their being discharged a low vitality of the photons from these radioactive sources.…”
Section: In-air Measurement Techniquementioning
confidence: 99%