IOL Formula Constants: Strategies for Optimization and Defining Standards for Presenting Data

Abstract: Purpose: To present strategies for optimization of lens power formula constants and to show options how to present the results adequately. Methods: A dataset of N=1601 preoperative biometric values, lens power data and postoperative refraction data was split into a training set and a test set using a random sequence. Based on the training set we calculated the formula constants for established lens calculation formulae with different methods. Based on the test set we derived the formula prediction error as di… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0
3

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 21 publications
(27 citation statements)
references
References 24 publications
(50 reference statements)
0
24
0
3
Order By: Relevance
“…Currently there are no generally accepted guidelines or recommendations for formula constant optimisation [ 15 , 20 , 29 ]. Where a formula is fully disclosed, and in the simple case of a formula with a single constant, it would be possible to reorganise the formula to solve for the formula constant (for each clinical case), and from the distribution of the formula constants the clinician could select statistical metrics such as the arithmetic or geometric mean or the median.…”
Section: Discussionmentioning
confidence: 99%
“…Currently there are no generally accepted guidelines or recommendations for formula constant optimisation [ 15 , 20 , 29 ]. Where a formula is fully disclosed, and in the simple case of a formula with a single constant, it would be possible to reorganise the formula to solve for the formula constant (for each clinical case), and from the distribution of the formula constants the clinician could select statistical metrics such as the arithmetic or geometric mean or the median.…”
Section: Discussionmentioning
confidence: 99%
“…Ein Wert, der den mittleren Fehler und die Standardabweichung gut abdeckt, ist die Wurzel der mittleren quadratischen Abweichung. Es bietet sich an, diesen Wert als Optimierungswert zu verwenden [24,25]. In Formeln mit einer Konstante sollten hierzu zumindest 80 Augen herangezogen werden [26].…”
Section: Iol-konstanten Und Optimierungunclassified
“…A value that covers the mean error and stan-dard deviation well is the root of the mean square deviation. It is a good idea to use this value as the optimization value [24,25]. In formulae with a constant, the constant should be based on data from at least 80 eyes [26].…”
Section: Iol Constants and Optimizationmentioning
confidence: 99%
“…Um die Formeln nun also an verschiedene Kunstlinsendesigns anzupassen, gibt es in den Formeln spezifische Konstanten, die zumeist entweder in die Berechnung der ELP bzw. der Linsenstärke eingehen [24] und die Formel an die jeweiligen Umstände, z.B. die spezifische Linse und den spezifischen Operateur, anpassen sollen.…”
Section: Stellschraubenunclassified
“…Dies kann jedoch an verschiedenen Werten orientiert werden: entweder bezogen auf den Mittelwert oder auf den Median oder auf den quadratischen Mittelwert des Vorhersagefehlers. Langenbucher et al schlagen hierzu beispielsweise einen Levenberg-Marquardt-Algorithmus vor [24]. Für welches Verfahren man sich auch entscheidet, man sollte seine optimierten Werte auf jeden Fall anhand zweier unterschiedlicher Kontrollgruppe kreuzvalidieren.…”
Section: Stellschraubenunclassified