Strategies for formula constant optimisation for intraocular lens power calculation

Abstract: Background To investigate modern nonlinear iterative strategies for formula constant optimisation and show the application and results from a large dataset using a set of disclosed theoretical-optical lens power calculation concepts. Methods Nonlinear iterative optimisation algorithms were implemented for optimising the root mean squared (SoSPE), the mean absolute (SoAPE), the mean (MPE), the standard deviation (SDPE), the median (MEDPE), as well as the 90% confidence interval (CLPE) of the prediction error … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
26
0
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 13 publications
(28 citation statements)
references
References 24 publications
0
26
0
2
Order By: Relevance
“…Adjusting IOL constants specifically for eyes after LVC does not seem intuitive, as these constants must depend on the ablation profile/amount of correction and ablation zone and require sufficient case numbers. Unless the surgical site has unusually large numbers of eyes with prior LVC, constants from eyes without prior LVC (e.g., from IOLCON [platform for characteristics of intraocular lenses and the optimization of lens constant], previously the ULIB [user group for laser interference biometry] site) should be used 16 , 17 , 18 . Additionally, interpretation of IOL power prediction accuracy studies on eyes after LVC is often difficult.…”
Section: Reviewmentioning
confidence: 99%
“…Adjusting IOL constants specifically for eyes after LVC does not seem intuitive, as these constants must depend on the ablation profile/amount of correction and ablation zone and require sufficient case numbers. Unless the surgical site has unusually large numbers of eyes with prior LVC, constants from eyes without prior LVC (e.g., from IOLCON [platform for characteristics of intraocular lenses and the optimization of lens constant], previously the ULIB [user group for laser interference biometry] site) should be used 16 , 17 , 18 . Additionally, interpretation of IOL power prediction accuracy studies on eyes after LVC is often difficult.…”
Section: Reviewmentioning
confidence: 99%
“…Ein Wert, der den mittleren Fehler und die Standardabweichung gut abdeckt, ist die Wurzel der mittleren quadratischen Abweichung. Es bietet sich an, diesen Wert als Optimierungswert zu verwenden [24,25]. In Formeln mit einer Konstante sollten hierzu zumindest 80 Augen herangezogen werden [26].…”
Section: Iol-konstanten Und Optimierungunclassified
“…Formeln mit mehreren Konstanten benötigen höhere Fallzahlen und andere Optimierungsstrategien, z. B. den Levenberg-Marquard-Algorithmus oder die Interior-Point-Methode [24]. Haigis verwendete eine einfache multiple lineare Regression mit 2 Variablen.…”
Section: Iol-konstanten Und Optimierungunclassified
See 2 more Smart Citations