2018 IEEE 38th International Conference on Electronics and Nanotechnology (ELNANO) 2018
DOI: 10.1109/elnano.2018.8477460
|View full text |Cite
|
Sign up to set email alerts
|

Investigation Thermal Conductivity of Biological Materials by Direct Heating Thermistor Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 4 publications
0
3
0
2
Order By: Relevance
“…It is found that the accuracy of determining the volume content depends on the difference in the thermal conductivity coefficients of the components. In order to observe the required measurement accuracy, it is necessary to choose a research algorithm [21], depending on the values of the difference in the thermal conductivity coefficients of the components.…”
Section: Discussion Of the Results Of Studies Of Thermophysical Propementioning
confidence: 99%
See 1 more Smart Citation
“…It is found that the accuracy of determining the volume content depends on the difference in the thermal conductivity coefficients of the components. In order to observe the required measurement accuracy, it is necessary to choose a research algorithm [21], depending on the values of the difference in the thermal conductivity coefficients of the components.…”
Section: Discussion Of the Results Of Studies Of Thermophysical Propementioning
confidence: 99%
“…It should be noted that the thermistor has a shell of glass or epoxy resin, and there is an error in determining the thermistor resistance and the nonlinear nature of the temperature dependence of thermistor resistance. Therefore, it is necessary to introduce additional proportionality coefficients into the calculation formula (1), which are determined by testing on reference fluids with known TPP [21,22].…”
Section: Substantiation Of the Mathematical Dependence Of The Thermentioning
confidence: 99%
“…ISSN: 2278-0181 http://www.ijert.org require precise temperature measurement in the limited temperature range. For instance, Kumar et al [10] used thermistors instantaneous monitoring of the temperature of the prosthetic device while Tymchik et al [11] used them for determination coefficient of thermal conductivity for biological materials.…”
Section: International Journal Of Engineering Research and Technology (mentioning
confidence: 99%
“…Відношення T t   є швидкістю зростання градієнта температури робочої поверхні УЗвипромінювача, що складається не тільки з п'єзоелектричного перетворювача, а ще і з корпусних, конструкційних деталей, шарів, що узгоджують акустичний опір, кріпильних елементів та інших частин, кожна з яких своєю чергою має власну теплоємність [9,10]. І кожен із цих компонентів буде брати участь у теплообміні (в разі зміни температури п'єзоелемента) залежно від його власної теплоємності [8].…”
Section: виклад основного матеріалу дослідженняunclassified