2020
DOI: 10.3390/app10186191
|View full text |Cite
|
Sign up to set email alerts
|

Investigation on the Differential Quadrature Fabry–Pérot Interferometer with Variable Measurement Mirrors

Abstract: Due to the common path structure being insensitive to the environmental disturbances, relevant Fabry–Pérot interferometers have been presented for displacement measurement. However, the discontinuous signal distribution exists in the conventional Fabry–Pérot interferometer. Although a polarized Fabry–Pérot interferometer with low finesse was subsequently proposed, the signal processing is complicated, and the nonlinearity error of sub-micrometer order occurs in this signal. Therefore, a differential quadrature… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…Therefore, the initial resolution of the grating-based encoder is about 4 to 40 μm ( Table S3, Supplementary Material ). On the other hand, the initial resolution of the interferometry-based encoder is based on the laser wavelength and the optical structure [ 2 , 12 ], and its initial resolution is about 0.16 μm or 0.32 μm, depending on its interferometer factor [ 13 ]. There have been several times where deviations have existed between the grating-based encoder and the interferometry-based encoder.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, the initial resolution of the grating-based encoder is about 4 to 40 μm ( Table S3, Supplementary Material ). On the other hand, the initial resolution of the interferometry-based encoder is based on the laser wavelength and the optical structure [ 2 , 12 ], and its initial resolution is about 0.16 μm or 0.32 μm, depending on its interferometer factor [ 13 ]. There have been several times where deviations have existed between the grating-based encoder and the interferometry-based encoder.…”
Section: Methodsmentioning
confidence: 99%
“…Advanced encoder systems are usually based on laser interferometers, due to their high initial resolution and the connection to the definition of the meter [ 1 ]. The common initial resolutions of the laser interferometers are about 0.32 μm or 0.16 μm, depending on the optical structure [ 2 ] ( Table S1, Supplementary Material ). The initial resolution of the laser interferometer is several times higher than that of a grating-based encoder system [ 3 ], and laser interferometers also have the feature of error reduction [ 4 , 5 , 6 ].…”
Section: Introductionmentioning
confidence: 99%
“…Using a combination of laser triangulation sensors and a contact probe, not only the distance of two parallel surfaces but also the difference between surface shape contours can be measured to micrometer-scale accuracy [2]. With a multi-path laser interferometer, a new computational model for step gauge calibration was proposed based on synthesis technology [3], and a differential quadrature Fabry-Pérot interferometer was proposed separately [4]. In this measurement system, the nonlinearity error can be improved effectively and the DC offset during the measurement procedure can be eliminated.…”
Section: Length Measurementmentioning
confidence: 99%
“…Reproduced from Refs. [ 19 , 25 , 28 , 32 , 39 , 40 , 56 , 85 , 94 , 95 , 96 , 106 , 107 ] Sensors Journal, Materials Journal, Applied Sciences Journal, Fibers Journal and Journal of Functional Biomaterials of the MDPI. Reproduced from Refs.…”
mentioning
confidence: 99%