2021 7th International Conference on Electrical Energy Systems (ICEES) 2021
DOI: 10.1109/icees51510.2021.9383641
|View full text |Cite
|
Sign up to set email alerts
|

Investigation on Photovoltaic System based Asymmetrical Multilevel Inverter for Harmonic Mitigation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…Such inverters may offer the control of active and reactive power and additional functionalities for PQ improvement. For instance, in [24] and [26] the authors proposed the method of controlling a three-phase, three-wire PV inverter, which, apart from supplying active and reactive power to the grid, can be used to reduce harmonic currents generated by non-linear loads.…”
Section: Inverter Topologymentioning
confidence: 99%
“…Such inverters may offer the control of active and reactive power and additional functionalities for PQ improvement. For instance, in [24] and [26] the authors proposed the method of controlling a three-phase, three-wire PV inverter, which, apart from supplying active and reactive power to the grid, can be used to reduce harmonic currents generated by non-linear loads.…”
Section: Inverter Topologymentioning
confidence: 99%
“…In this section, several kinds of multilevel inverters are compared on the basis of output voltage produced, the number of switches used, voltage sources used, IGBT devices used, total standing voltage (TSV), and the THD of various configurations, as given in Table 2. The MLI circuit proposed in [3,6] produces eleven levels of output voltage with different switch counts. In [11], the proposed topologies produce thirteen levels of output voltage, whereas the THD is reduced.…”
Section: Comparative Analysismentioning
confidence: 99%
“…The input voltage can be boosted by synthesizing capacitor voltage [5]. Integrating the solar PV system with the inverter is the main goal of the power quality improvement, and the performance of an asymmetric multilevel inverter with different PWM approaches for harmonic suppression is also examined [6]. Three induction motors are driven by a cascaded multilevel inverter using a hybrid control approach.…”
Section: Introductionmentioning
confidence: 99%
“…(13) Equation 14 presents the nonlinear equations required to obtain the triggering angles. (14) Solving Equation 14gives 13 triggering angles from which 12 orders (5,7,11,13,17,19,23,25,29,31,35,34) of harmonics are removed. Figure 5 shows the implementation of SHE method for the 27-level RMC .…”
Section: Modes Of Operationmentioning
confidence: 99%