2018
DOI: 10.5604/01.3001.0010.5636
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the Electromagnetic Shielding Effectiveness of Needle Punched Nonwoven Fabrics Produced from Stainless Steel and Carbon Fibres

Abstract: aaa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0
2

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 14 publications
0
10
0
2
Order By: Relevance
“…The UPF of the treated samples were obtained used 'Ultra Violet Transmittance Fabric Analyzer-lab sphere-USA. The UPF values are calculated automatically, in accordance with Australia/ Newzeland standard AS/NZS 4399:1996.The antimicrobial activity of the treated fabrics was examined against Staphylococcusaureus, ImprovINg ANtIbActerIAl ANd UltrAvIolet propertIes of cottoN ... [45].…”
Section: Testing and Analysismentioning
confidence: 99%
“…The UPF of the treated samples were obtained used 'Ultra Violet Transmittance Fabric Analyzer-lab sphere-USA. The UPF values are calculated automatically, in accordance with Australia/ Newzeland standard AS/NZS 4399:1996.The antimicrobial activity of the treated fabrics was examined against Staphylococcusaureus, ImprovINg ANtIbActerIAl ANd UltrAvIolet propertIes of cottoN ... [45].…”
Section: Testing and Analysismentioning
confidence: 99%
“…Many research papers describe SE evaluation from different perspectives, i.e., measurement techniques [1,2,3,4,5,6,7], composition of materials [8,9,10,11,12,13,14,15,16,17], influence of washing/drying cycles on values of SE of fabrics [18,19,20], or calculation of SE [4,21,22,23,24,25,26,27,28,29,30,31]. SE measurement is commonly performed by a coaxial transmission line method specified in ASTM 4935-10 [1,2,3,4,6,8,9,10,12,14,17,18] by measuring the insertion loss with a dual transverse electromagnetic (TEM) cell [3,5], or by measurement in a free space, shielding box, or shielding room with receiving and transmitting antennas [7,15,19,20].…”
Section: Introductionmentioning
confidence: 99%
“…SE measurement is commonly performed by a coaxial transmission line method specified in ASTM 4935-10 [1,2,3,4,6,8,9,10,12,14,17,18] by measuring the insertion loss with a dual transverse electromagnetic (TEM) cell [3,5], or by measurement in a free space, shielding box, or shielding room with receiving and transmitting antennas [7,15,19,20]. The papers which focus on measurement techniques of various electrically conductive fabrics usually present basic equations for SE calculation [4,21,22,23,24,25,26,27,28] (SI units are used in all formulas unless otherwise stated) as shown in Equation (1).…”
Section: Introductionmentioning
confidence: 99%
“…6 Therefore, numerous studies related to the manufacturing of conductive fabrics for EMSE applications at different frequency ranges have been completed. 720…”
mentioning
confidence: 99%
“…6 Therefore, numerous studies related to the manufacturing of conductive fabrics for EMSE applications at different frequency ranges have been completed. [7][8][9][10][11][12][13][14][15][16][17][18][19][20] Woven fabrics are any textiles consisting of at least two sets of yarns (warp and weft) that interlace perpendicularly to each other on a weaving machine. Taking into account that a satisfactory level of EMSE can be obtained by arranging the conductive yarns in an orthogonal grid, woven fabrics have been considered for EMSE applications in the textile industry.…”
mentioning
confidence: 99%