2014
DOI: 10.1109/tpwrs.2013.2285585
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the Dynamic Stability of Microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
67
0
6

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 177 publications
(73 citation statements)
references
References 14 publications
0
67
0
6
Order By: Relevance
“…However, it is impossible to find a Lyapunov function candidate to obtain a limit lower than I max through the choice of w min from (18) because the closed-loop system (16) is an RL circuit with a voltage source. Note that the actual limit of I depends on the small parasitic resistance r. As it can be seen from (19), when the value of r is significant (not zero), the maximum limit of the current will reduce. However, the current-limiting property below I max is still guaranteed and this holds independently from the filter, i.e.…”
Section: Current-limiting Propertymentioning
confidence: 99%
“…However, it is impossible to find a Lyapunov function candidate to obtain a limit lower than I max through the choice of w min from (18) because the closed-loop system (16) is an RL circuit with a voltage source. Note that the actual limit of I depends on the small parasitic resistance r. As it can be seen from (19), when the value of r is significant (not zero), the maximum limit of the current will reduce. However, the current-limiting property below I max is still guaranteed and this holds independently from the filter, i.e.…”
Section: Current-limiting Propertymentioning
confidence: 99%
“…In addition, previous contributions have exposed that harmonic interactions phenomena arise in controlled microgrids; however, they have not been still fully explored and understood [1], [9], [13], [37]. Therefore, the inherent harmonic cross-coupling, the resonances of the system and the interaction among the network, the control and the power electronic devices, lead to the apparition of non-characteristic harmonic components which are supposed to not exist.…”
Section: Fast-time Domain Harmonic Assessmentmentioning
confidence: 99%
“…or unfavorable operating scenarios overlooked in the design and evaluation stages [1], [4], [5]. In this way, this gap has been recognized and recently addressed in the open literature, albeit incipient.…”
mentioning
confidence: 99%
“…It has been assumed that the asynchronous generator is ideal, and hence the generator power is given by [18]:…”
Section: Aerodynamics Subsystemmentioning
confidence: 99%