2008
DOI: 10.1016/j.epsr.2007.05.019
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of performance of UPFC without DC link capacitor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
18
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(18 citation statements)
references
References 13 publications
0
18
0
Order By: Relevance
“…If a large amount of DGs using renewable energy are installed to a distribution system, voltage deviations and fluctuations based on output power fluctuation of DGs become a significant problem which cannot be solved by only tap changing for a load ratio control transformer (LRT) in substation and step voltage regulators (SVRs), due to relatively slow behavior. As a countermeasure against this problem, some control methods that use mainly reactive power controllers such as flexible ac transmission systems (FACTS) [1]- [3] or reactive power control of distributed generators [4]- [12], have been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…If a large amount of DGs using renewable energy are installed to a distribution system, voltage deviations and fluctuations based on output power fluctuation of DGs become a significant problem which cannot be solved by only tap changing for a load ratio control transformer (LRT) in substation and step voltage regulators (SVRs), due to relatively slow behavior. As a countermeasure against this problem, some control methods that use mainly reactive power controllers such as flexible ac transmission systems (FACTS) [1]- [3] or reactive power control of distributed generators [4]- [12], have been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…The mentioned advantages are achieved while the multiple dc sources are used to generate the output voltage waveform [4]. In recent years, MULTILEVEL inverters are one of the most versatile and powerful components that are utilized in many industrials such as FACTS devices [5] & [6], HVDC [7] & [8], etc. Various topologies for multilevel inverters have been introduced over the past 20 years, the most popular topologies are the diode-clamped [9], flying capacitor [10] and cascaded H-bridge topologies [11].…”
Section: Introductionmentioning
confidence: 99%
“…In addition, voltage regulation by OLTC has not reached a fundamental solution for power quality considering the power factor. As a countermeasure to this problem, the use of reactive power controllers, such as additional static VAR compensators (SVCs) [6][7][8][9][10][11] or the reactive power control system by the inclusion of an inverter with distributed generators [12][13][14][15][16][17][18] has been proposed. The literature [19] has discussed rapid and precise tap control online.…”
Section: Introductionmentioning
confidence: 99%