1993
DOI: 10.1021/ac00068a014
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of helium inductively coupled plasma-mass spectrometry for the detection of metals and nonmetals in aqueous solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
31
1

Year Published

1994
1994
1996
1996

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 42 publications
(33 citation statements)
references
References 26 publications
1
31
1
Order By: Relevance
“…Mass spectral interferences resulting from argon polyatomic species are reduced when He-based plasmas are applied as ionization sources, because He essentially is monoisotopic, and occurs at a low mass [11,12,20,24,25,27,30,35,36,[39][40][41][42]. The three isotopes of Ar ( 36 Ar + , 38 Ar + , and 40 Ar + ) along with polyatomic species containing Ar such as 40 Ar 16 O + , 40 Ar 40 Ar + , 40 Ar 35 Cl + interfere with the determination of certain isotopes, e.g.…”
Section: Potentials and Drawbacks Of Helium Icp Dischargesmentioning
confidence: 99%
See 3 more Smart Citations
“…Mass spectral interferences resulting from argon polyatomic species are reduced when He-based plasmas are applied as ionization sources, because He essentially is monoisotopic, and occurs at a low mass [11,12,20,24,25,27,30,35,36,[39][40][41][42]. The three isotopes of Ar ( 36 Ar + , 38 Ar + , and 40 Ar + ) along with polyatomic species containing Ar such as 40 Ar 16 O + , 40 Ar 40 Ar + , 40 Ar 35 Cl + interfere with the determination of certain isotopes, e.g.…”
Section: Potentials and Drawbacks Of Helium Icp Dischargesmentioning
confidence: 99%
“…The smaller size of He ICP and smaller electrical conductivity of helium lead to higher electric fields [46]. The presence of a high electric field in He ICP can lead to an undesirable secondary discharge to the MS interface [20,24,25,47,49]. In short, interface-linked discharges are very strong when the He ICP is used instead of the Ar ICP as an ionization source for mass spectrometry, even for the injection of gaseous samples into the plasma [20].…”
Section: Potentials and Drawbacks Of Helium Icp Dischargesmentioning
confidence: 99%
See 2 more Smart Citations
“…He ICP have been investigated as an alternative ion source for analytical mass spectrometry (198)(199)(200) (194,197). To sustain a He ICP and interface to mass analyzer, some modifications of the load coil, plasma torch and impedance network are necessary.…”
Section: Helium Plasmasmentioning
confidence: 99%