1998
DOI: 10.2172/665987
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of flammable gas and thermal safety issues for retrieval of waste from Tank 241-AN-105

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2002
2002
2003
2003

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(12 citation statements)
references
References 15 publications
0
12
0
Order By: Relevance
“…A degassing strategy using the two mixer pumps proposed for retrieval of AN-105 was developed based on the mitigation of SY-101 during Phase B pump operations (Caley et al 1998). The mixer pumps proposed for AN-105 are significantly more powerful than the mixer pump in SY-101; at their minimum operating speed of 700 rpm, they approximate the maximum performance of the SY-101 mixer pump at its maximum practical speed of 1000 rpm.…”
Section: Mixer Pump Degassingmentioning
confidence: 99%
See 1 more Smart Citation
“…A degassing strategy using the two mixer pumps proposed for retrieval of AN-105 was developed based on the mitigation of SY-101 during Phase B pump operations (Caley et al 1998). The mixer pumps proposed for AN-105 are significantly more powerful than the mixer pump in SY-101; at their minimum operating speed of 700 rpm, they approximate the maximum performance of the SY-101 mixer pump at its maximum practical speed of 1000 rpm.…”
Section: Mixer Pump Degassingmentioning
confidence: 99%
“…The work described above was performed in 1998 (Caley et al 1998) and 1999. (a) During this time the most urgent safety issue at Hanford was the waste level growth phenomenon occurring in SY-101.…”
Section: Improving the Models And Predictionsmentioning
confidence: 99%
“…By early December the jets had mixed most of the gas-bearing sediment layer because gas releases for the remainder of Phase B testing were relatively small. A degassing strategy using the two mixer pumps proposed for retrieval of AN-105 was developed based on the mitigation of SY-101 during Phase B pump operations (Caley et al 1998). The mixer pumps proposed for AN-105 are significantly more powerful than the mixer pump in SY-101; at their minimum operating speed of 700 rpm, they approximate the maximum performance of the SY-101 mixer pump at its maximum practical speed of 1000 rpm.…”
Section: Mixer Pump Degassingmentioning
confidence: 99%
“…This gas release resulted from four 20minute mixer pump runs at 360, 510, 720, and 920 rpm at a fixed angle. The calculated energy supplied to the waste by the pump during this period was approximately 18.2 kW-hr (Caley et al 1998). A single mixer pump in AN-105, operated at 700 rpm for 24 minutes, was calculated to supply equivalent energy for a roughly equivalent waste disturbance.…”
Section: Mixer Pump Degassingmentioning
confidence: 99%
See 1 more Smart Citation