2016
DOI: 10.1186/s12938-016-0133-x
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of blood flow in the external carotid artery and its branches with a new 0D peripheral model

Abstract: BackgroundPatient-specific modelling in clinical studies requires a realistic simulation to be performed within a reasonable computational time. The aim of this study was to develop simple but realistic outflow boundary conditions for patient-specific blood flow simulation which can be used to clarify the distribution of the anticancer agent in intra-arterial chemotherapy for oral cancer.MethodsIn this study, the boundary conditions are expressed as a zero dimension (0D) resistance model of the peripheral vess… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
31
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(31 citation statements)
references
References 54 publications
(31 reference statements)
0
31
0
Order By: Relevance
“…In real clinical scenarios, however, flow boundary conditions are not always available (19). As a result, the boundary conditions for CFD simulation were typically assumed with statistic or mean values obtained from the literature (7,20). This may create inaccuracies on an individual basis, especially at areas with complex geometry, which may lead to errors in the simulation of outcomes.…”
Section: Discussionmentioning
confidence: 99%
“…In real clinical scenarios, however, flow boundary conditions are not always available (19). As a result, the boundary conditions for CFD simulation were typically assumed with statistic or mean values obtained from the literature (7,20). This may create inaccuracies on an individual basis, especially at areas with complex geometry, which may lead to errors in the simulation of outcomes.…”
Section: Discussionmentioning
confidence: 99%
“…11. A steady state analysis is performed to understand the hemodynamics at peak systole with inlet velocity of 0.93 m/s applied at inlet and at the outlets a constant pressure of 30 mmHg is applied [39]. The variation of diameter along the three branches of the carotid artery is calculated and a location where the diameter is minimum is located as indicated in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Any artery above 6 mm in diameter is generally considered as large artery and we can also see from the plots that the shear rate is above 100 s 1 . Blood can be considered as Newtonian fluid for lumen diameter greater than 6 mm and also for shear rates above 100 s 1 , however, when there is flow circulation or reverse flows Newtonian models do not give correct results [39].…”
Section: Resultsmentioning
confidence: 99%
“…Although it is useful to simulate the distribution of anticancer agent in the ECA for each patient, there are few reports on the application of computational fluid dynamics (CFD) to IAC analysis in head and neck cancer, including oral cancer [ 8 , 9 ]. To apply CFD as a tool to assist treatment, simulations must be conducted accurately within a reasonable computational time.…”
Section: Introductionmentioning
confidence: 99%
“…For realistic blood flow simulation, the pressure condition is particularly important because it determines the flow distribution among the arteries. In our previous study [ 9 ], we developed a model for the outflow boundary condition as a zero-dimensional (0D) resistance model of the peripheral vasculature, which consists of only resistance to be incorporated into the commercial three-dimensional (3D) flow simulation software. The new 0D model could provide physiological pressure at each outlet and allow accurate blood flow simulation in the ECA and its branches.…”
Section: Introductionmentioning
confidence: 99%