2022
DOI: 10.3390/en15103548
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of a Metallic Interconnect Extracted from an SOFC Stack after 40,000 h of Operation

Abstract: An in-depth investigation was performed on a metallic interconnect extracted from an SOFC stack operated for 40,000 h. The characterization was performed on the surface and the cross-section, paying attention to the evolution of the materials due to the interaction with the dual atmosphere of the stack under operating parameters. The interaction between materials (i.e., metal substrate, coatings and atmospheres) and stack components (i.e., current collectors and MIC) generated several modifications that affect… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 36 publications
(55 reference statements)
0
2
0
Order By: Relevance
“…[19][20][21][22] Still, an additional Cathode (air electrode) Contact Layer (CCL) can be applied to minimize the contact losses. 17,[23][24][25][26] Such a CCL can also level out insufficient contacting due to surface roughness related to manufacturing of the MIC and air electrode. 27 Here, contact pastes can be used which are initially applied onto the MIC or air electrode before stacking.…”
Section: List Of Symbolmentioning
confidence: 99%
“…[19][20][21][22] Still, an additional Cathode (air electrode) Contact Layer (CCL) can be applied to minimize the contact losses. 17,[23][24][25][26] Such a CCL can also level out insufficient contacting due to surface roughness related to manufacturing of the MIC and air electrode. 27 Here, contact pastes can be used which are initially applied onto the MIC or air electrode before stacking.…”
Section: List Of Symbolmentioning
confidence: 99%
“…Currently, some coating materials have shown potential application prospects; for example, Nb-coated stainless steel BPs exhibited a low degradation rate (~5.5 µV h −1 ) during the 14,000 h electrolysis cell test [39]. Mn-Co spinel-coated FSS BPs showed excellent stability over the 40,000 h SOFC stack test [40]. Therefore, the current research focuses on developing suitable coating technologies for commercial applications; the advantages and disadvantages of different coating methods for BPs are summarized in Table 1.…”
Section: Introductionmentioning
confidence: 99%