13th InterSociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems 2012
DOI: 10.1109/itherm.2012.6231582
|View full text |Cite
|
Sign up to set email alerts
|

Investigation and application of an advanced dual piezoelectric cooling jet to a typical electronics cooling configuration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 15 publications
0
9
0
Order By: Relevance
“…Figure 7c is a DCJ device developed by Garg et al, which mainly comprises of two-piezoelectric bimorph disks separated by a wall material with an orifice. Moreover, it is very compact and simple to integrate into the overall system [71]. Although the present DCJ is only suited for the application with heat F I G U R E 6 Equivalent thermal circuit of the component heat source [42].…”
Section: Piezoelectric Dual Cooling Jetmentioning
confidence: 99%
“…Figure 7c is a DCJ device developed by Garg et al, which mainly comprises of two-piezoelectric bimorph disks separated by a wall material with an orifice. Moreover, it is very compact and simple to integrate into the overall system [71]. Although the present DCJ is only suited for the application with heat F I G U R E 6 Equivalent thermal circuit of the component heat source [42].…”
Section: Piezoelectric Dual Cooling Jetmentioning
confidence: 99%
“…Unlike beam fans, generating airflow in open space, diaphragm pumps require at least one chamber to create the pressure, and thus, the airflow. Despite diaphragm pumps are flexible in the chamber design, the performance of a diaphragm pump depends on factors such as the operating conditions of the PE actuator [57,58], the configuration of the chamber [57][58][59], and the structure of the inlet and outlet [60,61].…”
Section: Reciprocatingmentioning
confidence: 99%
“…de Bock et al [58] measured the PQ curves of a 40 mm by 40 mm by 1 mm dual-jet diaphragm pump using a standard flow bench, as shown in Fig. 23.…”
Section: Reciprocatingmentioning
confidence: 99%
See 1 more Smart Citation
“…Fewer studies have investigated the use of SJs for actual cooling applications. For example, De Bock et al [23] and Marron et al [24] explored the performance of SJs for heat sink cooling. These studies showed that SJs can provide significant cooling enhancement over natural convection and that under certain conditions, they outperform traditional fans, especially for equivalent power requirement.…”
mentioning
confidence: 99%