2015
DOI: 10.1063/1.4936012
|View full text |Cite
|
Sign up to set email alerts
|

Intraobserver reproducibility of parameters of standard and 2D speckle tracking echocardiography, dynamics of global longitudinal strain I in patients with acute primary anterior STEMI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0
2

Year Published

2016
2016
2020
2020

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 13 publications
0
3
0
2
Order By: Relevance
“…All echocardiography images were analyzed offline by a single independent ultrasound diagnostic specialist, who was without any information about patient history. 2022 All data were obtained on an ultrasound machine Vivid E9 (GE Healthcare) and saved on CD-ROM drives. Then, these images were transferred and analyzed with the software GE EchoPac.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…All echocardiography images were analyzed offline by a single independent ultrasound diagnostic specialist, who was without any information about patient history. 2022 All data were obtained on an ultrasound machine Vivid E9 (GE Healthcare) and saved on CD-ROM drives. Then, these images were transferred and analyzed with the software GE EchoPac.…”
Section: Methodsmentioning
confidence: 99%
“…Standard transthoracic echocardiography was performed at days 3 (T2), 7 (T3), and 14 (T4) and 6 months (T5) after STEMI onset (Vivid E9; GE Healthcare). 20,21 Serum was sampled at the same times and also at day 1 (T1) after STEMI onset. A scientific collaborator from the Department of Laboratory Diagnostics determined serum levels of sST2, NT-proBNP, and hCRP by an immunoenzymatic assay method.…”
Section: Methodsmentioning
confidence: 99%
“…Кроме оценки деформации миокарда, технология предлагает инструменты для изучения сложной биомеханики сердца и оценки вос-становления нарушенных в результате ИМ функций сердца. Ранее нами и коллегами показана высокая вну-три-и межоператорская воспроизводимость показате-лей 2D speckle tracking эхокардиографии, в том числе и GLS [12,13]. Установлено, что деформация у обследо-ванных больных улучшается уже к 7-м суткам, и эта динамика сохраняется к моменту выписки больного из стационара.…”
Section: Discussionunclassified
“…STEMI was diagnosed based on the third universal definition of MI [ 2 ]. Echocardiography was performed in all patients at Days 3 (T2), 7 (T3) and 14 (T4) and six months (T5) after STEMI onset (Vivid E9, GE Healthcare, Boston, MA, USA) [ 4 , 11 , 12 ]. The obtained images were stored on CD-ROM drives and then analyzed using GE EchoPAC software (GE, Healthcare, EchoPac 113, Boston, MA, USA).…”
Section: Methodsmentioning