1985
DOI: 10.1378/chest.87.6.720
|View full text |Cite
|
Sign up to set email alerts
|

Intracuff Pressures in Endotracheal and Tracheostomy Tubes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
72
0
7

Year Published

1996
1996
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 89 publications
(82 citation statements)
references
References 11 publications
3
72
0
7
Order By: Relevance
“…Ao insuflar o "cuff' ocorre um aumento da pressão em seu interior e essa pressão deve ser controlada em nível suficiente para manter o fluxo sangüíneo capilar na área de contato com o mesmo 1,18 . No entanto, pouca referência é feita em relação à quantidade de ml de ar a ser insuflada no "cuff' de modo a manter a sua pressão capilar da traquéia. Alguns autores 3,6,8 alertam para a importância de se manter uma pressão "intra-cuff' menor que a pressão capilar da traquéia (32mmHg) e indicam uma pressão entre 20 a 30 mmHg.…”
Section: Resultsunclassified
“…Ao insuflar o "cuff' ocorre um aumento da pressão em seu interior e essa pressão deve ser controlada em nível suficiente para manter o fluxo sangüíneo capilar na área de contato com o mesmo 1,18 . No entanto, pouca referência é feita em relação à quantidade de ml de ar a ser insuflada no "cuff' de modo a manter a sua pressão capilar da traquéia. Alguns autores 3,6,8 alertam para a importância de se manter uma pressão "intra-cuff' menor que a pressão capilar da traquéia (32mmHg) e indicam uma pressão entre 20 a 30 mmHg.…”
Section: Resultsunclassified
“…Concern regarding safety of such tubes has been expressed [3,6]. Suggested improvements include: appropriate size cuff diameter, preventing longitudinal creases [6], large-diameter, thin, highcompliance cuffs [1,5], improved cuff design (contour, material, high residual volume) combined with control of cuff inflation [4] and smaller diameter high-compliance cuffs with no intracuff invaginations [3]. A high-residual volume, high-compliance, thin-walled cuff, forming tiny transverse wrinkles obliterating the longitudinal slits, might seal off the longitudinal channelling of liquid at an intracuff pressure lower than the mucosal capillary pressure.…”
Section: Discussionmentioning
confidence: 99%
“…2,5,6 The intracuff pressure can be affected by various factors, including environmental factors (e.g., intraoperative use of high airway pressure and nitrous oxide), patient factors (e.g., differences in the size of the trachea and the position of the intratracheal cuff), and cuffrelated factors (e.g., differences in cuff compliance and diameter). [7][8][9][10] Positional change and neck movement after intubation can displace an ETT in a patient's trachea. [11][12][13][14][15][16][17][18] Intratracheal migration of the ETT due to a change in patient positioning can result in a change in the ETT cuff pressure because the trachea is not cylindrical.…”
Section: Résumémentioning
confidence: 99%
“…9 A conventional ETT has a cylindrical cuff, whereas the shape of the TaperGuard TM ETT (Covidien, Athlone, Ireland) cuff tapers distally to reduce microaspiration and ventilator-associated pneumonia. 24,25 The objective of our prospective randomized study was to compare the ETT cuff pressure in the TaperGuard ETT vs the conventional ETT after a change from the supine to the lateral flank position.…”
Section: Résumémentioning
confidence: 99%