Intra- und postoperative elektrophysiologische Diagnostik

Abstract: Within the context of treatment with cochlear implants (CIs), different electrical and electrophysiological diagnostic procedures are applied both intra- and postoperatively. These assess electrical measures from the CI and electrophysiological measures from CI patients, respectively. The electrophysiological diagnostic procedures comprise measurement of electrically evoked compound action potentials of the auditory nerve, the registration of electrically evoked auditory brainstem potentials and the assessment… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 55 publications
0
4
0
2
Order By: Relevance
“…B. dann auf, wenn die Sicht erschwert ist [76]. Bei Fehlbildungen kann ein Reflex oft nicht ausgelöst werden [77].…”
Section: Intraoperatives Monitoringunclassified
“…B. dann auf, wenn die Sicht erschwert ist [76]. Bei Fehlbildungen kann ein Reflex oft nicht ausgelöst werden [77].…”
Section: Intraoperatives Monitoringunclassified
“…The amplitude grows with increasing insertion depth, reductions reveal possible mechanical interactions with intracochlear structures, most probably with the basilar membrane. If the reduction can be reversed by correcting the electrode position, a low impact on residual hearing may be expected, otherwise substantial damage must be assumed [4,5]. -Electrical Compound Action Potentials (ECAP) of the auditory nerve evoked by intracochlear electrical stimulation to assess the neural responses of the auditory nerve.…”
Section: Implant (Receiver-stimulator)mentioning
confidence: 99%
“…If the insertion is stopped at the onset of amplitude decrease and the electrode is pulled back or the direction of insertion is changed, the response amplitude may recover. In this way, the maximum insertion depth for hearing preservation can be determined [5,41,42]. There is a good correlation between intraoperative changes and postoperative hearing (▶Fig.…”
Section: Cochlear Implant Surgery With Hearing Preservationmentioning
confidence: 99%
See 2 more Smart Citations