Abstract: Robot-assisted minimally invasive surgery has many advantages compared to conventional open surgery and also certain drawbacks: it causes less operative trauma and faster recovery times but does not allow for direct tumour palpation as is the case in open surgery. This article reviews state-of-the-art intra-operative tumour localisation methods used in robot-assisted minimally invasive surgery and in particular methods that employ force-based sensing, tactile-based sensing, and medical imaging techniques. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
19
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 26 publications
(19 citation statements)
references
References 83 publications
0
19
0
Order By: Relevance
“…6, we demonstrate a case where a patient had a tumor detectable by RMI and pathology but this lesion was invisible on MRI. As mentioned in the introduction section, MRI is useful for predicting tumor size of cancer foci greater than 10 mm in diameter [4]. Due to the higher resolution (the positional 14 resolution of the Phantom OmniTM is 0.055mm; the force resolution is 0.003N; and, the scanning resolution is ±0.5mm), the probe is sensitive to the existence of a small tumor buried near the surface of the organ.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…6, we demonstrate a case where a patient had a tumor detectable by RMI and pathology but this lesion was invisible on MRI. As mentioned in the introduction section, MRI is useful for predicting tumor size of cancer foci greater than 10 mm in diameter [4]. Due to the higher resolution (the positional 14 resolution of the Phantom OmniTM is 0.055mm; the force resolution is 0.003N; and, the scanning resolution is ±0.5mm), the probe is sensitive to the existence of a small tumor buried near the surface of the organ.…”
Section: Discussionmentioning
confidence: 99%
“…However, robotic surgery throws down a new challenge, because it deprives surgeons of haptic feedback and therefore tissue stiffness assessment afforded by their fingers or dissection instruments. Therefore, dissection planes and in particular, bladder neck sparing or nerve sparing increments can be decided only by pre-operative assessments about tumor stage and visual cues [4]. 4 It is possible that the loss of haptic feedback is one reason why robotic surgery has failed to deliver convincingly (at least to date) significant improvements in functional outcomes relative to open or conventional laparoscopic surgery.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Several articles have reviewed the medical robotics for MIS applications (eg,) most of which are outdated. Moreover, a few studies reviewed the recent developments in soft robotics actuators and sensors .…”
Section: Introductionmentioning
confidence: 99%
“…2 By manipulating either intrinsic Young modulus or actuating a pair of antagonistic actuator of soft robots in different ways, stiffness of the soft robots can also be tuned. 3 Several articles have reviewed the medical robotics for MIS applications (eg, [4][5][6][7][8][9][10][11][12] ) most of which are outdated. Moreover, a few studies reviewed the recent developments in soft robotics actuators and sensors.…”
mentioning