2002
DOI: 10.1148/radiol.2232010704
|View full text |Cite
|
Sign up to set email alerts
|

Interpretation of Digital Mammograms: Comparison of Speed and Accuracy of Soft-Copy versus Printed-Film Display

Abstract: Interpretation with soft-copy display is likely to be useful with digital mammography and is unlikely to significantly change accuracy or speed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
47
0
7

Year Published

2003
2003
2017
2017

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 85 publications
(59 citation statements)
references
References 9 publications
5
47
0
7
Order By: Relevance
“…In addition, these results are in agreement with our previous evaluation of displays (also including a medical-grade grayscale display) using images obtained with CR [17], as well as the evaluation of capture devices (including standard CR) visualized using a medical-grade grayscale display. Previous studies have compared film-screen mammography to digitized films [9][10][11], and similar to the present study, these reports found no significant differences in diagnostic accuracy. In our study, we obtained AUC mean values that were similar to the values reported by Powell [9], Gitlin et al [10], and Pisano et al [11].…”
Section: Discussionsupporting
confidence: 89%
See 2 more Smart Citations
“…In addition, these results are in agreement with our previous evaluation of displays (also including a medical-grade grayscale display) using images obtained with CR [17], as well as the evaluation of capture devices (including standard CR) visualized using a medical-grade grayscale display. Previous studies have compared film-screen mammography to digitized films [9][10][11], and similar to the present study, these reports found no significant differences in diagnostic accuracy. In our study, we obtained AUC mean values that were similar to the values reported by Powell [9], Gitlin et al [10], and Pisano et al [11].…”
Section: Discussionsupporting
confidence: 89%
“…Previous studies have compared film-screen mammography to digitized films [9][10][11], and similar to the present study, these reports found no significant differences in diagnostic accuracy. In our study, we obtained AUC mean values that were similar to the values reported by Powell [9], Gitlin et al [10], and Pisano et al [11]. However, these previous studies did not evaluate digital cameras and low-cost displays.…”
Section: Discussionsupporting
confidence: 89%
See 1 more Smart Citation
“…Both hard-and software of mammography review stations has improved significantly over the last few years. Dedicated mammography review stations now allow to switch almost instantaneously between different image layouts including a sequential magnified quadrant zoom, with softcopy reading speed approaching or even surpassing that of batch film reading [56,57]. Viewing the entire image piece by piece in full resolution may be tedious, but necessary to ensure that no microcalcifications are overlooked.…”
Section: Impact On Workflowmentioning
confidence: 99%
“…In breast imaging, resolution is an important factor for diagnosing lesions on digital or digitized mammograms [9] [10] [11] [12]. In recent years, 4 K or 8 K diagnostic displays have come to be implemented; in particular, high-resolution displays are currently favored for mammography [13].…”
Section: Introductionmentioning
confidence: 99%