Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
42
0
2

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 68 publications
(45 citation statements)
references
References 25 publications
1
42
0
2
Order By: Relevance
“…From a methodological point of view, agreement rate is an indicator for a new, experimental diagnostic method [11]. According to our results, ABVS and UE both displayed substantial inter-examiner agreement (ABVS: κ  = 0.62, UE: κ  = 0.65).…”
Section: Discussionsupporting
confidence: 51%
See 1 more Smart Citation
“…From a methodological point of view, agreement rate is an indicator for a new, experimental diagnostic method [11]. According to our results, ABVS and UE both displayed substantial inter-examiner agreement (ABVS: κ  = 0.62, UE: κ  = 0.65).…”
Section: Discussionsupporting
confidence: 51%
“…FDA has recommended approval for use in screening of women with dense breast parenchyma because it is unsusceptible to breast density [10]. However, with its striking practical advantages mentioned above, ABVS is accepted by other countries, and its diagnostic performance was not inferior to HHUS [1117]. …”
Section: Introductionmentioning
confidence: 99%
“…The Acuson S2000TM ABVS is a highly advanced ultrasound system, which acquires the full-field volume of the breast, provides an efficient and comprehensive analysis of 3D data, and ensures accurate and consistent results for diagnosis. In addition, every section of the lesion can be easily displayed by the ABVS; more importantly, it is operator independent, providing more reproducible and reliable data [6,7]. Based on the advances of the ABVS, the detection rate of breast lesions has improved significantly, particularly for minor lesions.…”
Section: Discussionmentioning
confidence: 99%
“…For the detection of breast lesions, ABVS possesses certain advantages over US: 1) ABVS provides automated and standardized scanning; 2) reconstructed images can be saved and transmitted for later analysis, thereby facilitating remote consultation by allowing an assistant medical technician or radiographer to operate the device, a junior physician to analyze the images and report the findings, and a senior physician to interpret the findings and provide the final impression or diagnosis; 3) ABVS is less dependent on operator idiosyncrasies, so ABVS can reduce the impact of operator bias, thereby improving standardization and reproducibility (11,13,14); 4) overlooking a lesion is less probable with ABVS; compared to the small field of view provided by traditional 3D US (5 cm 2 ), ABVS offers a wider field of view covering the entire breast volume with one Japanese study demonstrating a whole breast visualization rate of up to 98% (15)(16)(17); and 5) unlike other imaging modalities, lesions that are not detected during breast US are not typically documented; however, ABVS has the potential to provide complete documentation (18).…”
Section: Advantages Of Abvs Over Us In Detecting Breast Lesionsmentioning
confidence: 99%