2018
DOI: 10.1021/acs.analchem.7b04150
|View full text |Cite
|
Sign up to set email alerts
|

Internal Calibration Potentiometric Aptasensors for Simultaneous Detection of Hg2+, Cd2+, and As3+ Based on a Screen-Printed Carbon Electrodes Array

Abstract: An all-solid-state potentiometric aptasensor array based on a multichannel disposable screen-printed carbon electrode (SPCE) was demonstrated for the simultaneous detection of Hg, Cd, and As by open circuit potential (OCP) technology. The potential of the channel with an internal calibration DNA sequence (IC-DNA) was employed as the internal calibration potential (ICP) to subtract the background signal generated by the detection system, providing a built-in correction methodology. As a result, the developed ap… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 47 publications
(12 citation statements)
references
References 55 publications
0
12
0
Order By: Relevance
“…An aptasensor was developed for the simultaneous determination of heavy metal ions (Hg 2+ , Cd 2+ , and As 3+ ) using potentiometry [84]. A multichannel screen-printed carbon electrode array was used as a transducer, with electrodes modified with rGO and gold dendrimers.…”
Section: Ionsmentioning
confidence: 99%
“…An aptasensor was developed for the simultaneous determination of heavy metal ions (Hg 2+ , Cd 2+ , and As 3+ ) using potentiometry [84]. A multichannel screen-printed carbon electrode array was used as a transducer, with electrodes modified with rGO and gold dendrimers.…”
Section: Ionsmentioning
confidence: 99%
“…Positive and negative examples of the use of logarithmic and semilogarithmic calibration plots can be found in the recent literature. Some reports relate analytical response with logarithm of concentration (or activity), while others use a nonlinear (logarithmic) concentration axis. Usefulness of the former representation in quantitative analysis is limited. The latter may (in some cases) be defensible if a logarithmic dependency is expected for a particular technique, and the authors do not claim “linearity”.…”
Section: Use Of Logarithm In Calibration Plotsmentioning
confidence: 99%
“…As for other folding-and dynamics-based electrochemical biosensors, multiple uses (up to three) were possible by introducing a regeneration step. To address the need of portable devices, researches focused on the development of highly sensitive aptasensors based on screen-printed electrodes (SPE) [74,94]. Li et al [94] proposed a simple label-free aptasensor on gold SPE using the issAP08_Cd 2+ aptamer with a thiol linker as a bioreceptor.…”
Section: Cadmiummentioning
confidence: 99%
“…A potentiometric aptasensor array for the simultaneous detection of Cd 2+ and Hg 2+ was developed by Tang et al [74]. A multichannel disposable screen-printed carbon electrode (SPCE) modified with reduced graphene oxide and dendritic nanostructured gold was used to increase the stability and the effective area of SPCE channels.…”
Section: Cadmiummentioning
confidence: 99%