2012
DOI: 10.1016/j.jchromb.2012.04.027
|View full text |Cite
|
Sign up to set email alerts
|

Interference by metabolites and the corresponding troubleshooting during the LC–MS/MS bioanalysis of G004, a bromine-containing hypoglycemic agent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…This is a common practice in industry, where effect of co-medication is widely studied according to a survey carried out by EBF [49]. On the other hand, very few scientific papers follow this approach [50][51][52][53]. Ansermot et al studied the selectivity of a method for the quantification of selective serotonin reuptake inhibitors by spiking plasma samples with 63 common medications in the psychiatric population [52].…”
Section: Selectivity and Specificitymentioning
confidence: 99%
“…This is a common practice in industry, where effect of co-medication is widely studied according to a survey carried out by EBF [49]. On the other hand, very few scientific papers follow this approach [50][51][52][53]. Ansermot et al studied the selectivity of a method for the quantification of selective serotonin reuptake inhibitors by spiking plasma samples with 63 common medications in the psychiatric population [52].…”
Section: Selectivity and Specificitymentioning
confidence: 99%
“…The stream selection valve of MS was set to waste at 3 min until the next injection. The selective procedure of the MS condition of G004 and the IS was reported in our previous study (Hu et al, 2012;Hu et al, 2014).…”
Section: Mass Spectrometric Conditionsmentioning
confidence: 99%
“…It is generally accepted that acidic compounds are readily deprotonated to form anions for the negative ESI in mobile phases with a pH above their pK a (Bonfilio et al, 2010;Yan et al, 2011). In the earlier studies, the poor detection limits of LC-MS/MS for G004 in the negative-ion mode were reported using a near-neutral or typical basic eluent with high concentration of ammonium acetate (Li et al, 2007;Liu et al, 2011;Hu et al, 2012;Hu et al, 2014). Unexpectedly, in this study, the acidic mobile phase without the addition of the ammonium acetate promoted both the chromatographic separation and the peak shape.…”
Section: Improvement Of the Sensitivity On The Determination Of G004 mentioning
confidence: 99%
See 2 more Smart Citations