2008
DOI: 10.1590/s0103-84782008000300017
|View full text |Cite
|
Sign up to set email alerts
|

Interface homem-máquina para controle de processos de resfriamento com ar forçado visando à economia de energia

Abstract: RESUMO Apresenta

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
2

Year Published

2011
2011
2021
2021

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 3 publications
0
2
0
2
Order By: Relevance
“…A microprocessor machine with human-machine interface (HMI) was developed by TERUEL et al (2008), aiming to open loop control of systems with forced air cooling of vegetables, with the function of providing variable airflow rates according to the amount of produce to cool, in order to keep within the range of the recommended values to ensure an appropriate cost-benefit. The development of this equipment was based on the fact that the existing cooling systems currently operate in accordance with the airflow pre-determined in the project depending on the amount of product to cool.…”
Section: Introductionmentioning
confidence: 99%
“…A microprocessor machine with human-machine interface (HMI) was developed by TERUEL et al (2008), aiming to open loop control of systems with forced air cooling of vegetables, with the function of providing variable airflow rates according to the amount of produce to cool, in order to keep within the range of the recommended values to ensure an appropriate cost-benefit. The development of this equipment was based on the fact that the existing cooling systems currently operate in accordance with the airflow pre-determined in the project depending on the amount of product to cool.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, for this work, the division of the objects of study of the articles was considered according to Table 5 for the corresponding quantification of the articles on RB&A. The division presented above and in Figure 5 (bellow) does not refer to the parameters measured in the articles, but to the scope of the article itself, such as, for instance, in the article "Interface homem-máquina para controle de processos de resfriamento com ar forçado visando à economia de energia" 46 , published in the journal Ciência Rural and which is focused on the development of an equipment that will support farm production.…”
mentioning
confidence: 99%
“…Ainda na linha de eficiência energética, pesquisas recentes têm procurado melhorar esta combinação através do uso de inversores de frequência e do controle automático da rotação dos motoventiladores de sistemas de secagem, estes mecanismos atuam diretamente sobre a potência útil mecânica do equipamento insuflador de ar, gerando vazões de ar variáveis no sistema e reduzindo o consumo de energia ao evitar o funcionamento em carga nominal (SOUZA et al, 2009;TERUEL et al, 2008;SILVA, 2010).…”
Section: Temperaturaunclassified