Interconnecting single-phase backup generation to the utility distribution system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
2

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 2 publications
0
3
0
2
Order By: Relevance
“…For example, the output power can be of: (i) direct current or alternate current (which can additionally have a constant or variable frequency); (ii) fixed or variable voltage amplitude; (iii) different voltage levels; among others. Due to these factors, the alternative energy sources in DG schemes imply in the use of power electronics interfaces, as well as dedicated controllers and communication capabilities, aiming at an efficient utilization of the available resources [2,5]. Power converters are used to adjust voltage and current in each source to other sources, storage devices and loads, or to the mains network.…”
Section: Integration Of Energy Sourcesmentioning
confidence: 99%
See 1 more Smart Citation
“…For example, the output power can be of: (i) direct current or alternate current (which can additionally have a constant or variable frequency); (ii) fixed or variable voltage amplitude; (iii) different voltage levels; among others. Due to these factors, the alternative energy sources in DG schemes imply in the use of power electronics interfaces, as well as dedicated controllers and communication capabilities, aiming at an efficient utilization of the available resources [2,5]. Power converters are used to adjust voltage and current in each source to other sources, storage devices and loads, or to the mains network.…”
Section: Integration Of Energy Sourcesmentioning
confidence: 99%
“…It acts also on the total load current, i L , to compensate for current harmonics and reactive power, in a way that the total source current, i S , is also harmonic-free and in phase with the fundamental source voltage, resulting in a unitary displacement factor. The UPQC controller using the instantaneous power theory (or p-q Theory) is convenient either for single-or three-phase systems to obtain its reference signals for the compensation process [1,5,6]. To apply this theory in a single-phase microgrid, a modification in the system is required to calculate the power signals.…”
Section: The Hfac-based Microgridmentioning
confidence: 99%
“…Fault current infeed from DG has an adverse impact on fuse saving [9]. Figure 4 shows how DG near a fused lateral adds to the current flowing through the fuse.…”
Section: Fuse Blowingmentioning
confidence: 99%
“…Para esse ensaio é projetada uma carga RLC em paralelo, com frequência de ressonância igual à frequência fundamental da rede de distribuição, calculada por (25). E fator de qualidade igual a 2, calculado pela equação (26).…”
Section: Ensaio Com Carga Rlcunclassified
“…* + = ‰ OE 2п 8" OE8&ƒ%) ) ) (29) Sendo " OE8&ƒ%) a tensão rms nominal do sistema, é a potência ativa média da carga, ‰ OE é o fator de qualidade da carga calculado em (26), & é a frequência de ressonância da carga definida por (25).…”
Section: Rede De Distribuiçãounclassified