2004
DOI: 10.1016/j.jqsrt.2003.12.008
|View full text |Cite
|
Sign up to set email alerts
|

Intercomparison of retrieval codes used for the analysis of high-resolution, ground-based FTIR measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
328
0
3

Year Published

2009
2009
2023
2023

Publication Types

Select...
7
2
1

Relationship

2
8

Authors

Journals

citations
Cited by 376 publications
(337 citation statements)
references
References 40 publications
3
328
0
3
Order By: Relevance
“…The retrieval methodology uses two spectral microwindows with spectral width that depends on the NH 3 background concentration determined for the observation stations and location (wider window for stations with background concentrations less than one ppb (Rodgers, 2000) is used, implemented in the SFIT4 algorithm (Pougatchev et al, 1995;Hase et al, 2004Hase et al, , 2006. There are a number of species that can interfere to some extent in both windows, with the major species being H 2 O, CO 2 and O 3 and the minor species N 2 O, HNO 3 , CFC-12, and SF 6 .…”
Section: Ftir-nh 3 Retrievalmentioning
confidence: 99%
“…The retrieval methodology uses two spectral microwindows with spectral width that depends on the NH 3 background concentration determined for the observation stations and location (wider window for stations with background concentrations less than one ppb (Rodgers, 2000) is used, implemented in the SFIT4 algorithm (Pougatchev et al, 1995;Hase et al, 2004Hase et al, , 2006. There are a number of species that can interfere to some extent in both windows, with the major species being H 2 O, CO 2 and O 3 and the minor species N 2 O, HNO 3 , CFC-12, and SF 6 .…”
Section: Ftir-nh 3 Retrievalmentioning
confidence: 99%
“…We use the same code (PROFFIT; Hase et al, 2004) for MUSICA's NDACC/FTIR and MetOp/IASI remote-sensing retrievals. In so doing, we want to ensure that the respective ground-and space-based data products are as consistent as possible.…”
Section: Remote Sensing Of Water Isotopologuesmentioning
confidence: 99%
“…The Bruker FTIR instrument (IFS 120 M, which made in Ettlingen of German) was used for observations. The specifications for atmospheric spectrum measurements are based on the Network for the Detection of Atmospheric Composition Change [29,30]. Observation of greenhouse gases has been carried out for several years [31].…”
Section: Ground-based Measurement Of Chmentioning
confidence: 99%