Interaction between effects of ambient parameters and those of other important parameters on electrospinning of PEI/NMP solution

Abstract: By electrospinning method, fibers are produced with diameters ranging from hundred nanometers up to a few micrometers. In this study, the influence of ambient temperature and relative humidity on the morphology of electrospun polyetherimide (PEI) fibers at varying electrospinning parameters such as solution concentration, applied voltage, and tip-to-collector distance was investigated. 1-methyl-2-pyrrolidinone was used as a solvent for PEI. Morphology and diameter of electrospun PEI fibers were examined by fie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 23 publications
(24 reference statements)
0
8
0
Order By: Relevance
“…The electrospun solution was cellulose acetate (CA) dissolved in in acetone/dimethylformamide/ethanol (2:2:1) [82].Huang et al, reported that with increasing the relative humidity the average diameter fibers of electrospun poly(acrylonitrile) (PAN) solution witch dissolved in DMF increased, at conditions (concentration = 10% w/w, voltage = 28 KV, flow rate = 1mL/h and needle to collector distance =18 cm). Also they electrospunpolysulfone (PSU) with concentration 28% w/w and the same process conditions, found that average diameter of produced fiber increased with increasing relative humidity and fiber size distributions became broader [83].Oğulata and İçoğlu studied effect of relative humidity on morphology of electrospunpolyetherimide (PEI) solutions dissolved in 1-methyl-2 pyrrolidinone at conditions (concentration = 18% w/w, voltage = 20KV and needle to collector distance = 15cm). They observed that the average diameter of produced fiber increased by 103% with increasing relative humidity from 30% to 70%.…”
Section: Solution Properties Such As Concentration Molecularmentioning
confidence: 99%
“…The electrospun solution was cellulose acetate (CA) dissolved in in acetone/dimethylformamide/ethanol (2:2:1) [82].Huang et al, reported that with increasing the relative humidity the average diameter fibers of electrospun poly(acrylonitrile) (PAN) solution witch dissolved in DMF increased, at conditions (concentration = 10% w/w, voltage = 28 KV, flow rate = 1mL/h and needle to collector distance =18 cm). Also they electrospunpolysulfone (PSU) with concentration 28% w/w and the same process conditions, found that average diameter of produced fiber increased with increasing relative humidity and fiber size distributions became broader [83].Oğulata and İçoğlu studied effect of relative humidity on morphology of electrospunpolyetherimide (PEI) solutions dissolved in 1-methyl-2 pyrrolidinone at conditions (concentration = 18% w/w, voltage = 20KV and needle to collector distance = 15cm). They observed that the average diameter of produced fiber increased by 103% with increasing relative humidity from 30% to 70%.…”
Section: Solution Properties Such As Concentration Molecularmentioning
confidence: 99%
“…In general, the results of this study suggests no significant difference in fibre thickness for scaffolds produced at either low or elevated humidities. This contrasts with the case of the effects of humidity on solution electrospinning, where numerous studies reported significant variations in fibre size and morphology Pelipenko et al [7]; Ogulata and Icoglu [8]; Bisht et al [9]; Lu and Xia [10]; Medeiros et al [11]; Casper et al [12]; Nezarati et al [13]. As solution electrospinning relies on solvent evaporation for fibre solidification, the effect of humidity could be expected to be more pronounced compared with melt electrospinning, where fibre solidification is due to polymer cooling.…”
Section: Discussionmentioning
confidence: 88%
“…Electrospinning is sensitive to environmental conditions such as temperature and humidity. This sensitivity has been well documented in several studies investigating the effect of humidity on solution electrospinning [7][8][9][10][11][12][13][14]. As the formation of fibres in solution electrospinning is through solvent evaporation following extrusion, the process is highly susceptible to the humidity [15].…”
Section: Introductionmentioning
confidence: 91%
See 1 more Smart Citation
“…They found maximum increase in fiber diameter for 20% PEI solution at the range of relative humidity (RH) 30–70% and temperature at 15–35 °C and lowest diameter at 15–35 °C for all the humidity levels used. 38 Hence, both the optimum relative humidity and temperature are necessary to obtain defect free nanofibers.…”
Section: Limiting Factors and Their Influence On Morphology Of Nanofi...mentioning