2014
DOI: 10.1016/j.radonc.2014.07.016
|View full text |Cite
|
Sign up to set email alerts
|

Intensity-modulated radiotherapy of the prostate: Dynamic ADC monitoring by DWI at 3.0T

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
40
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(42 citation statements)
references
References 27 publications
2
40
0
Order By: Relevance
“…The report that how FDG-PET and MRI reflected for effect of treatment in the diagnosis instrument of these days came to be accomplished [4][5][6]. When the increase of the ADC level of the site where prostate cancer is present in significantly correlated with a decrease of the PSA according to the report of Yamaguchi et al in DWI the radiotherapy half a year later, we report it [1].…”
Section: Discussionmentioning
confidence: 73%
“…The report that how FDG-PET and MRI reflected for effect of treatment in the diagnosis instrument of these days came to be accomplished [4][5][6]. When the increase of the ADC level of the site where prostate cancer is present in significantly correlated with a decrease of the PSA according to the report of Yamaguchi et al in DWI the radiotherapy half a year later, we report it [1].…”
Section: Discussionmentioning
confidence: 73%
“…Diffusion MRI sequences have been shown to predict response to RT [86,87] earlier than gross tumor size changes or metabolic changes based on FDG PET-CT [88]. Both the baseline apparent diffusion coefficient (ADC) and changes in ADC, specifically increase in ADC after RT, correlate with tumor control and patient outcome after radiotherapy [89][90][91][92][93][94]. The UCLA group recently published the results of a pilot study utilizing a spin echo-based diffusion sequence on the tri- 60 Co system to track changes in diffusion over the course of RT for six patients [95].…”
Section: Adaptive Radiotherapymentioning
confidence: 99%
“…Under external radiotherapy of the prostate, the ADC value in carcinomas of the prostate increases significantly but does not change substantially in healthy prostate tissue [27]. DCE-MRI: DCE-MRI includes the fast acquisition of T1w sequences after bolus application of a gadolinium-containing contrast agent and is established in clinical oncology as a biomarker [28].…”
Section: Dwi Dce-mri 1 H-mrsmentioning
confidence: 99%
“…By using a combined endorectal body phased-array coil, the sensitivity and the positive predictive value for the detection of prostate cancer could be increased in individual studies even in 3 T MRI examinations [27]. The sole use of a body phased-array coil at 3 T as widely used in practice is justified by the good detection of significant tumors [28].…”
Section: Endorectal Coilmentioning
confidence: 99%