Integration of Selective Area Anodized AgCl Thin Film with AlGaN/GaN HEMTs for Chloride Ion Detection

Abstract: We have demonstrated a selective area AgCl anodization process, which can be integrated with the fabrication of AlGaN/GaN high electron mobility transistors ͑HEMTs͒ for chloride ion detection. A limit of detection of chloride ion concentration achieved was 1 ϫ 10 −8 M using a 20 ϫ 50 m anodized Ag/AgCl layer on the HEMT gate sensing area. Unlike the conventional open-circuit potential measurement used for the electrochemical measurement, the drain current of the HEMT was monitored as the output signal in our s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…39 also shows the real time pressure detection with the polarized PVDF gated HEMT. The drain current of HEMT sensor showed a rapid decrease in less than 5 s when the ambient pressure was changed to 20 psig [242][243][244][245][246][247]. A further decrease of the drain current for the HEMT sensor was observed when the chamber pressure increased to 40 psig.…”
Section: Pressure Sensingmentioning
confidence: 94%
“…39 also shows the real time pressure detection with the polarized PVDF gated HEMT. The drain current of HEMT sensor showed a rapid decrease in less than 5 s when the ambient pressure was changed to 20 psig [242][243][244][245][246][247]. A further decrease of the drain current for the HEMT sensor was observed when the chamber pressure increased to 40 psig.…”
Section: Pressure Sensingmentioning
confidence: 94%
“…The HEMT sensor immobilized with the AgCl thin film has also demonstrated an excellent response to chloride ion concentrations. 25,26 As illustrated in Figure 8, the sensor showed rapid responses with the chloride ion concentrations in the exposed solutions. This encouraging result shows the possibility of using chloride ion concentrations to calibrate the dilution factor during the measurement of biomarkers in EBC.…”
Section: Discussionmentioning
confidence: 98%
“…GaN based materials are chemically stable, biocompatible, and stable in high temperature and reliable detections of biological agents in real time have been proved by using AlGaN/GaN HEMT based biosensors [8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23]. These sensors also (F. Ren).…”
Section: Introductionmentioning
confidence: 99%
“…have small size and low cost, and only need small quantity of test samples, thanks to the matured semiconductor microfabrication technique [8][9][10][11][12][13][14][15][16][17][18][19][20][21]. The antibody-immobilized AlGaN/GaN HEMT-based biosensors have been used to detect Botulinum toxin type-A with a limit of detection (LOD) below 1 ng/ml with good reproducibility [8].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation