2020
DOI: 10.1016/j.istruc.2019.10.009
|View full text |Cite
|
Sign up to set email alerts
|

Integration of CFRP strips as an internal shear reinforcement in reinforced concrete beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 23 publications
0
4
0
1
Order By: Relevance
“…No caso do estudo de AMAIREH et al [20], o reforço ao cisalhamento de CFRP foi aplicado internamente ao concreto, acoplado à armadura, em formas de faixas. A aplicação do reforço aumentou de maneira significativa a resistência da viga e, assim como o presente estudo, aumentou a rigidez das vigas.…”
Section: Ensaios Experimentaisunclassified
“…No caso do estudo de AMAIREH et al [20], o reforço ao cisalhamento de CFRP foi aplicado internamente ao concreto, acoplado à armadura, em formas de faixas. A aplicação do reforço aumentou de maneira significativa a resistência da viga e, assim como o presente estudo, aumentou a rigidez das vigas.…”
Section: Ensaios Experimentaisunclassified
“…Every prism was cast with one reinforcing bar (anode) and one stainless steel bar (cathode). To reach the desired corrosion level (7.5% or 15% mass loss), the period of accelerated corrosion was estimated using Faraday's law [20]: (1) where mi is the mass loss (g); M is the atomic weight of the metal = 56 g for Fe; I is the corrosion current (A) = i × sa; i is the corrosion current density (μA/cm 2 ); sa is the surface area of the corroded steel (cm 2 ); T is the time (s); z is the valence of the corroding metal (2 for iron); F is Faraday's constant = 96,500 A•s.…”
Section: Specimen Fabricationmentioning
confidence: 99%
“…Bond failure can occur by splitting of the concrete cover between a spliced bar and the side face of the lap splice beam. The bond between the reinforcing bar and the surrounding concrete might fail through shearing off of the concrete keys between reinforcing bar ribs, resulting in bar slip which is called pull out bond failure [1][2][3]. Splitting bond failure is the most common bond failure, especially in the absence of confinement.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, PET bers are proposed to be added into concrete in order to increase ductility. ACI code 2019 and the most codes given the factor of safety for shear more than the exural to avoid the shear failure because the shear failure is brittle compared with the ductile exural failure [5][6][7]. Several investigations in last decade (Kandasamy and Murugesan, 2012[8]; prahallada 2013 [9]; Ms. K. Ramadevi 2015 [10]; Mr. Govind V. Dhanani 2016 [11]; B.S.…”
Section: Introductionmentioning
confidence: 99%
“…Al-Tulaian 2016; Mustafa Ahmed Abbas 2018 [1]; Subhi A. Ali [12]) were focused on the effect of waste plastic on the mechanical properties and the shear behavior. (Ha Minh [13]; M. Sivaraja [14]; Layla Amaireh [5]; Armoosh et al [15]; Abdelmonem Masmoudi[16]; Shahad AbdulAdheem Jabbaret [17]; Maath G. Alkubaisi et al [18]) were focused on the effect of CFRP and GFRP on the shear behavior.…”
Section: Introductionmentioning
confidence: 99%