2016
DOI: 10.1109/jstqe.2015.2492361
|View full text |Cite
|
Sign up to set email alerts
|

Integrated Space-Division Multiplexer for Application to Data Center Networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(10 citation statements)
references
References 35 publications
0
10
0
Order By: Relevance
“…Minimizing f 3 cost would reduce the effect of return losses in the multimode waveguide, while minimizing f 4 cost would reduce the effect of reflection losses in the single-mode waveguide. On the other hand, maximizing both f 1 cost and f 2 cost would reduce the dependence of the wavelengths in both multimode and single-mode waveguides, respectively.…”
Section: Solution Of the Coupled-mode Equations And Gratings' Designmentioning
confidence: 99%
See 2 more Smart Citations
“…Minimizing f 3 cost would reduce the effect of return losses in the multimode waveguide, while minimizing f 4 cost would reduce the effect of reflection losses in the single-mode waveguide. On the other hand, maximizing both f 1 cost and f 2 cost would reduce the dependence of the wavelengths in both multimode and single-mode waveguides, respectively.…”
Section: Solution Of the Coupled-mode Equations And Gratings' Designmentioning
confidence: 99%
“…(21) has to be minimized, and the coefficient of the second term of fourth equation has to be minimized. Accordingly, f 4 cost is defined as in Eq. (29).…”
Section: Solution Of the Coupled-mode Equations And Gratings' Designmentioning
confidence: 99%
See 1 more Smart Citation
“…If the number of sensors in a Smart City starts to increase, fast communication, and data processing is necessary for fast decision making. In this case, all technology that has been developed for fast, robust, and low power consumption optical interconnects in data centers can be applied on a FTTS network [73,79,80]. Here, central nodes that collect information from different sensors are the data centers.…”
Section: Advanced Photonic Technologies For Smart Citiesmentioning
confidence: 99%
“…Multiple modes can be used in a few-mode fiber in order to achieve space-division multiplexing (SDM) [2]. In addition, SDM technology is also becoming attractive for optical interconnects in data centers [3], [4].…”
Section: Introductionmentioning
confidence: 99%