1982
DOI: 10.1080/00022470.1982.10465533
|View full text |Cite
|
Sign up to set email alerts
|

Integrated Sampling and Analysis Methods for Determining NOxEmissions at Electric Utility Plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

1984
1984
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…The A-P methods were developed for determination of NO* emissions in electric utility and nitric acid plant stacks (8).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The A-P methods were developed for determination of NO* emissions in electric utility and nitric acid plant stacks (8).…”
Section: Resultsmentioning
confidence: 99%
“…Two Method 7 samples were taken every 10 min. The purpose of the duplicate Method 7 samples was to accurately determine the precision for this method that would be used in subsequent statistical analysis (8). The purpose of the NO* analyzer was to observe any real-time variations in the process emissions that might help explain any unusual results and to serve as the standard for determination of the collection efficiency of NO* (as N03") in the A-P impingers.…”
Section: Resultsmentioning
confidence: 99%
“…Water depth, turbidity, Electrical Conductivity (EC), and Dissolved Oxygen (DO) of marsh water was measured in the field with a portable multimeter, which was previously calibrated, while the other physical and chemical characteristics of the water samples were analyzed in the lab according to the methods of the American Public Health Association (APHA) [13] . The gravimetric method [14] , five −day Biological Oxygen Demand (BOD) test [15] , and Colorimetric method [16] were used to determine Total Dissolved Solids (TDS), BOD, and NO 2 − , respectively. Ca 2+ , Mg 2+ , and Total Hardness (TH) were determined using Ethylenediaminetetraacetic acid (EDTA) method.…”
Section: Methodsmentioning
confidence: 99%
“…At 28 days the quality of SF concrete is constantly higher than the quality of the practically identical Portland bond concrete. As the extent of SF builds, the usefulness of solid reductions in any case its momentary mechanical property, for example, 28-day compressive quality improves [8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%