Mechanical Properties of Structural Films 2001
DOI: 10.1520/stp10983s
|View full text |Cite
|
Sign up to set email alerts
|

Integrated Platform for Testing MEMS Mechanical Properties at the Wafer Scale by the IMaP Methodology

Abstract: ABSTRACT:A new instrument to accurately and verifiably measure mechanical properties across an entire MEMS wafer is under development. We have modified the optics on a conventional microelectronics probe station to enable three-dimensional imaging while maintaining the full working distance of a long working distance objective. This allows standard probes or probe cards to be used. We have proceeded to map out mechanical properties along a wafer column by the Interferometry for Material Property Measurement (I… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2001
2001
2008
2008

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…We have recently demonstrated an integrated platform to determine mechanical properties by this method at the wafer scale [29]. Along a wafer column, we found little variation in GPa , but significant changes in and residual stress.…”
Section: Discussionmentioning
confidence: 89%
“…We have recently demonstrated an integrated platform to determine mechanical properties by this method at the wafer scale [29]. Along a wafer column, we found little variation in GPa , but significant changes in and residual stress.…”
Section: Discussionmentioning
confidence: 89%
“…In that case, however, active techniques must be employed. Such techniques are under development [34]. Bent-beam structures are a reasonable alternative in the absence of active methods.…”
Section: Discussionmentioning
confidence: 99%
“…Once implemented, electrical actuation adds little in cost or time to the measurement process and can be used to obtain and average multiple data points from beams subject to either tensile or compressive residual strain. An integrated platform to accomplish interferometry of actuated devices at the wafer scale is under development [34].…”
Section: Case Of Tensile Residual Stressmentioning
confidence: 99%
“…Although, the MEMS beam is not completely rigid on both ends; there is still a dependence on the compliance of the anchor. This study does not fully consider the effects of the beam take-off angle [43][44][45][46][47][48][49]. The out-of-plane displacement (see Fig.…”
Section: Beam Theory: Fmed-fixed Beamsmentioning
confidence: 99%