2005
DOI: 10.2166/wst.2005.0134
|View full text |Cite
|
Sign up to set email alerts
|

Integrated operation of sewer system and WWTP by simulation-based control of the WWTP inflow

Abstract: In recent years numerical modelling became a standard procedure to optimise urban wastewater systems design and operation by integration. For dynamic control of the wastewater teatment plant (WWTP) inflow, a model-based predictive concept is introduced aiming at improving the receiving water quality. An on-line simulator running parallel to the real WWTP operation reflects the actual state of operation and provides this model information to a prognosis tool which determines the best option for the WWTP inflow.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0
2

Year Published

2006
2006
2019
2019

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 6 publications
0
6
0
2
Order By: Relevance
“…Weinreich et al 1997;Pleau et al 2001;Schütze et al, 2002, Zacharof et al, 2003Erbe and Schütze (2005), Butler and Schütze, 2005;Benedetti et al, 2008), case studies (e.g. Erbe et al, 2002;Seggelke et al, 2005), and novel optimisation methods (e.g. Brdys et Muschalla, 2008).…”
Section: Sewer Flow Control To Prevent Sewer Spill and Floodingunclassified
“…Weinreich et al 1997;Pleau et al 2001;Schütze et al, 2002, Zacharof et al, 2003Erbe and Schütze (2005), Butler and Schütze, 2005;Benedetti et al, 2008), case studies (e.g. Erbe et al, 2002;Seggelke et al, 2005), and novel optimisation methods (e.g. Brdys et Muschalla, 2008).…”
Section: Sewer Flow Control To Prevent Sewer Spill and Floodingunclassified
“…For example, McCorquodale et al (2005) used physical modeling to investigate the optimization of the hydraulic conditions of a high-purity oxygen-activated sludge. Also, Seggelke et al (2005) optimized the dynamic control of a treatment plant inflow by using an online simulator running parallel to the real WWTP operation; this provided model information to a prognosis tool which determines the best inflow options.…”
Section: Review Of Reported Optimization Modelsmentioning
confidence: 99%
“…Günümüzde ise evsel atıksu arıtma tesislerinin modellenmesi, birçok farklı amaç için kullanılmaktadır. Örneğin; Seggelke ve arkadaşları [8], evsel atıksu arıtma tesisinin modellenmesi kapsamına aşırı yağış koşullarının etkisini incelemiştir. Dinamik modelleme çalışmalarında yaşam döngüsü değerlendirmesi entegrasyonu ile evsel atıksuların nütrient geri kazanım potansiyeli tahmin edilebilmektedir [9].…”
Section: Introductionunclassified