2002
DOI: 10.1021/ac020185n
|View full text |Cite
|
Sign up to set email alerts
|

Integrated Microfluidic System Enabling (Bio)chemical Reactions with On-Line MALDI-TOF Mass Spectrometry

Abstract: A continuous flow micro total analysis system (micro-TAS) consisting of an on-chip microfluidic device connected to a matrix assisted laser desorption ionization [MALDI] time-of-flight [TOF] mass spectrometer (MS) as an analytical screening system is presented. Reaction microchannels and inlet/outlet reservoirs were fabricated by powderblasting on glass wafers that were then bonded to silicon substrates. The novel lab-on-a-chip was realized by integrating the microdevice with a MALDI-TOFMS standard sample plat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
82
0

Year Published

2005
2005
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 105 publications
(83 citation statements)
references
References 35 publications
(50 reference statements)
1
82
0
Order By: Relevance
“…A similar concept was explored by Brivio et al [67] using a closed, rather than open, microfluidic chip. Microchannels (200 mm wide and 100 mm deep) were machined by powder blasting into a borosilicate glass substrate.…”
Section: Microfluidic/target Integrationmentioning
confidence: 97%
See 1 more Smart Citation
“…A similar concept was explored by Brivio et al [67] using a closed, rather than open, microfluidic chip. Microchannels (200 mm wide and 100 mm deep) were machined by powder blasting into a borosilicate glass substrate.…”
Section: Microfluidic/target Integrationmentioning
confidence: 97%
“…Photograph of a vacuum-driven microfluidic reaction chip containing an open exit reservoir for MALDI laser access. The glass chip is integrated with into a standard MALDI plate [67].…”
Section: Microfluidic/target Integrationmentioning
confidence: 99%
“…Most approaches focused on biological MS integrated to microfluidic chips employ ESI [11][12][13][14][15][16][17][18] and only a few have used MALDI [19,20]. Although ESI and MALDI are often complimentary techniques, the preference of ESI interfaces between microchips and MS can be explained by the fundamentals behind the two ionization methods.…”
Section: Introductionmentioning
confidence: 99%
“…A continuous pressure driven self-activating flow on-chip microfluidic device connected to MALDI-TOF mass spectrometer has also been reported [20]. The integration was achieved by placing the microdevice on a standard MALDI sample plate, which had a rectangular hole milled to fit the entire device.…”
Section: Introductionmentioning
confidence: 99%
“…In other off-line approaches, the sample is dispensed from the chip using a piezoelectric dispenser [25], pumped through a spinning microfluidic disk [26], or sample droplets moved on a dielectric chip surface by electrowetting [27,28]. In a unique on-line approach, the vacuum of the mass spectrometer source is used to pull fluid through a microfluidic chip where it is subjected to UV MALDI as it exits the device [29,30]. A second on-line approach uses a rotating stainless steel ball coupled to an on-chip capillary electrophoresis for the separation of peptides [31].…”
mentioning
confidence: 99%