Instrument-independent cad spectral databases: absolute cross-section measurements in QQQ instruments

Abstract: The energy dependence of the cross section, cr(E), for the symmetric (resonant) charge transfer reaction Ar+(Ar,Ar)Ar+ was measured in our triple quadrupole (QQQ) tandem mass spectrometer. lOur cr(E), for P=0. [the range of collision energies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
16
0

Year Published

1988
1988
1996
1996

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(17 citation statements)
references
References 27 publications
1
16
0
Order By: Relevance
“…As the pressure increases from 1.4 to 2.9ϫ10 Ϫ4 Torr, the mean-free path for charge-exchange collision is estimated to decrease from about 28 to 13.5 cm. 15 This indicates that at higher pressure, there are more collisions at the near side to the source than at far side, i.e., the generation of the lower-energy neutrals is larger at higher pressure. Moreover, elastic scattering and second chargeexchange collisions are apt to occur at the higher pressure and they also produce lower-energy neutrals.…”
Section: Kinetic-energy Measurement Of a Neutral Stream Extracted Fromentioning
confidence: 93%
“…As the pressure increases from 1.4 to 2.9ϫ10 Ϫ4 Torr, the mean-free path for charge-exchange collision is estimated to decrease from about 28 to 13.5 cm. 15 This indicates that at higher pressure, there are more collisions at the near side to the source than at far side, i.e., the generation of the lower-energy neutrals is larger at higher pressure. Moreover, elastic scattering and second chargeexchange collisions are apt to occur at the higher pressure and they also produce lower-energy neutrals.…”
Section: Kinetic-energy Measurement Of a Neutral Stream Extracted Fromentioning
confidence: 93%
“…1-3. [42][43][44][45] Under such conditions one observes a poorly resolved MS/MS spectrum in Q3." Hence, it would not be possible to make a dynamically-correct determination of the relative abundance of progeny ions which are separated by only a few amu.…”
Section: Generic Mslms Databasementioning
confidence: 99%
“…Ar'(Ar,Ar)Ar~ [10] to determine the target thickness [B]L }, followed by ii) the experiment associated with figure 1(a) of [9].…”
Section: Accuracy In Trace Analysismentioning
confidence: 99%
“…Moreover, real-time trace analysis often involves unknown transient species (e.g., reactive environmental pollutants and/or products of their photooxidation). Characterization of such species would be facilitated if one could do spectral matching against a generic, instrument-independent MS/MS CAD spectral database comprised of known ionic substructures (see [10,11]). …”
mentioning
confidence: 99%
See 1 more Smart Citation