2017
DOI: 10.1016/j.atmosenv.2016.12.007
|View full text |Cite
|
Sign up to set email alerts
|

Influences of relative humidities and temperatures on the collection of C2-C5 aliphatic hydrocarbons with multi-bed (Tenax TA, Carbograph 1TD, Carboxen 1003) sorbent tube method

Abstract: Volatile organic compounds (VOCs) are measured with sorbent tubes followed by thermal desorption (TD) analysis. Water vapor in the atmosphere affects sampling breakthrough and results in low collection efficiency. This paper reports the effect of relative humidity (RH) and temperature on the collection of 57 ozone precursors with a multi-bed tube composed of three different strengths of adsorbents (Tenax TA, Carbograph 1 TD, and Carboxen 1003). Unacceptable breakthrough values for volatile C 2 -C 5 aliphatic c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 32 publications
(22 citation statements)
references
References 16 publications
1
21
0
Order By: Relevance
“…All pre-conditioned and sampled tubes were capped and shipped at 0 ℃. Insignificant breakthrough (<5%) was observed either in field or laboratory demonstration under this sampling flow and volume (Ho et al, 2017). Two sorbent tube samples were thus collected in each test and one field blank was collected on each sampling campaign.…”
Section: Guanzhongmentioning
confidence: 88%
See 2 more Smart Citations
“…All pre-conditioned and sampled tubes were capped and shipped at 0 ℃. Insignificant breakthrough (<5%) was observed either in field or laboratory demonstration under this sampling flow and volume (Ho et al, 2017). Two sorbent tube samples were thus collected in each test and one field blank was collected on each sampling campaign.…”
Section: Guanzhongmentioning
confidence: 88%
“…Duplicate samples were collected and the reproducibility was better than 95%. Detailed sampling and analytical method was shown in Ho et al (2017).…”
Section: 2chemical Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The loaded tubes were analyzed using a thermal desorption and gas chromatography/mass spectrometry (TD-GC/MS) method. In previous developmental work, humidity and temperature during sampling were found to impact significantly on the analyses; for this study, all sample collections were made under optimized conditions (Ho et al, 2017;Ho et al, 2018). Sixteen airborne carbonyls (including mono-and dicarbonyls) were collected over diurnal cycles (i.e., 20:00-08:00 local time [LT] and 08:00-20:00 LT) by 2,4-dintrophenyhydrozine (DNPH) coated-cartridges.…”
Section: Field Samplingmentioning
confidence: 99%
“…Sixteen airborne carbonyls (including mono-and dicarbonyls) were collected over diurnal cycles (i.e., 20:00-08:00 local time [LT] and 08:00-20:00 LT) by 2,4-dintrophenyhydrozine (DNPH) coated-cartridges. Detailed sampling and analytical procedures for VOCs and carbonyls can be found in previous publication (Ho et al, 2017;Dai et al, 2012). PM2.5 filter samples were sampled with mini-volume samplers (Model Mini-Vol, Air Metrics Co., Oregon, USA) with a flow rate of 5 L min -1 (Cao et al, 2005).…”
Section: Field Samplingmentioning
confidence: 99%