2010
DOI: 10.1016/j.matchemphys.2009.07.033
|View full text |Cite
|
Sign up to set email alerts
|

Influence of visco-elasto-plastic properties of magnetite on the elastic modulus: Multicyclic indentation and theoretical studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
25
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 48 publications
(27 citation statements)
references
References 37 publications
1
25
1
Order By: Relevance
“…A second point is that the procedure supposes a constant compliance of the system. As a matter of fact, we showed recently by molecular dynamic analysis that the bulk modulus is obtained by indentation instead of the Young's modulus [10]. Moreover, in the same paper we showed that the compliance of the system depends on the indentation conditions in accordance to the observations of Fischer-Cripps [9] on the effect of nature, geometry, mounting of the sample on the total compliance of the system.…”
Section: Introductionsupporting
confidence: 81%
See 1 more Smart Citation
“…A second point is that the procedure supposes a constant compliance of the system. As a matter of fact, we showed recently by molecular dynamic analysis that the bulk modulus is obtained by indentation instead of the Young's modulus [10]. Moreover, in the same paper we showed that the compliance of the system depends on the indentation conditions in accordance to the observations of Fischer-Cripps [9] on the effect of nature, geometry, mounting of the sample on the total compliance of the system.…”
Section: Introductionsupporting
confidence: 81%
“…In a previous work [10], we proposed a modification of Equation (3) taking into account all these aspects for the calculation of the elastic modulus:…”
Section: Elastic Modulusmentioning
confidence: 99%
“…(1). Since the frame compliance of the instrument, C f , depends on the sample/instrument couple and on the indentation test conditions in microindentation [21,55,56], its value must be determined for each set of indentation tests. For a coated system, the frame compliance can be determined by employing the model of Tricoteaux et al [5].…”
Section: Resultsmentioning
confidence: 99%
“…Such a negative value can be surprising but its variation is complex and the origins of such variation are large, like the frame compliance of the instrument, the mounting system, presence of glue or epoxy resin, indenter fixing, testing conditions, roughness, etc. [21,56]. On the other hand, its value can be also greatly affected by the scatter of the measurements of the composite reduced elastic modulus due to the substrate roughness and the variation of the film thickness.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation