2014
DOI: 10.1007/s11665-014-1043-3
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Surface Morphology on the Torsion Fracture of NiTi Endodontic Instruments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…While the Nitinol alloys provide the capability to follow the contours of the dental canal better than other available alloys due to its elastic qualities, the propensity to fracture under flexion/rotation is a significant concern. 209 Multiple investigators have studied bending and rotating fatigue in endodontic files and wires reporting effects related to file geometry, 209 processing, 22,61 composition, 210,211 radius of curvature, 212 torsional loading 213,214 and rate. 70 A few studies on wires and files are briefly discussed in this section in addition to fatigue testing on archwires.…”
Section: Mechanical Property Datamentioning
confidence: 99%
“…While the Nitinol alloys provide the capability to follow the contours of the dental canal better than other available alloys due to its elastic qualities, the propensity to fracture under flexion/rotation is a significant concern. 209 Multiple investigators have studied bending and rotating fatigue in endodontic files and wires reporting effects related to file geometry, 209 processing, 22,61 composition, 210,211 radius of curvature, 212 torsional loading 213,214 and rate. 70 A few studies on wires and files are briefly discussed in this section in addition to fatigue testing on archwires.…”
Section: Mechanical Property Datamentioning
confidence: 99%
“…Despite these advantages they are still prone to failure (14) , plastic deformations or even fracture, because of torque or many factors (15) (16) method of manufacture, surface treatment, speed, operator force or canal curvatures (17) It is necessary to observe the surface changes of rotary instruments because it considered an important factor in failure or fracture initiation (18) (19) Fracture of Ni-Ti instruments could occur with little or no visible evidence of plastic deformation; that could not be visualized without magnification (20) (21) Therefore, the only predictable way to prevent failure is to discard rotary files regularly after a certain number of uses (6) , especially in complex canal preparations; calcified canals & curved canals (2) . Also care must be taken while using these instruments and manufacturer's instructions must be followed.…”
Section: Introductionmentioning
confidence: 99%