2018
DOI: 10.1049/iet-smt.2017.0092
|View full text |Cite
|
Sign up to set email alerts
|

Influence of remote earth and impulse polarity on earthing systems by field measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(8 citation statements)
references
References 16 publications
(42 reference statements)
0
8
0
Order By: Relevance
“…A review of field testing and measurement of impulse tests on grounding systems was firstly performed, to present various test set-ups and arrangements adopted in previously published works [2,8,[11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. The study of soil behavior under impulse condition by means of field testing showed that the resistance decreased with increasing current [2,[12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. It was noted from these studies [2,[11][12][13][14][15][16][17][18][19][20][21][22]…”
Section: Review Of Field Testing and Measurementsmentioning
confidence: 99%
See 4 more Smart Citations
“…A review of field testing and measurement of impulse tests on grounding systems was firstly performed, to present various test set-ups and arrangements adopted in previously published works [2,8,[11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. The study of soil behavior under impulse condition by means of field testing showed that the resistance decreased with increasing current [2,[12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. It was noted from these studies [2,[11][12][13][14][15][16][17][18][19][20][21][22]…”
Section: Review Of Field Testing and Measurementsmentioning
confidence: 99%
“…The study of soil behavior under impulse condition by means of field testing showed that the resistance decreased with increasing current [2,[12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. It was noted from these studies [2,[11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] that the main concerns in the field measurements are the costs, logistics and time challenges. The guidelines were also found to be limited, due to the limited standards for field testing and measurements of grounding systems under high impulse conditions.…”
Section: Review Of Field Testing and Measurementsmentioning
confidence: 99%
See 3 more Smart Citations