In many publications, the characteristics of practical earthing systems were investigated under conditions involving fast-impulse currents of different magnitudes by field measurements. However, as generally known, in practice the transient current can normally reach several tens of kiloamperes. This paper therefore aimed to investigate the characteristics of a new electrode for grounding systems under high current magnitude conditions, and compare it with steady-state test results. The earth electrodes were installed in low resistivity test media, so that high impulse current magnitudes can be achieved. The effects of impulse polarity and earth electrode’s geometry of a new earth electrode were also quantified under high impulse conditions, at high currents (up to 16 kA).
One of the most important parameters of the performance of grounding systems is the soil resistivity. As generally known, the soil resistivity changes seasonally, hence the performance of grounding systems, at DC and under high impulse conditions. This paper presents the performance of grounding systems with two different configurations. Field experiments were set up to study the characteristics of the grounding systems seasonally at power frequency and under high impulse conditions. A review of field testing on practical grounding systems was also presented. It was found that the soil resistivity, RDC and impulse characteristics of grounding systems were improved over time, and the improvement was higher for electrodes that have more contact with the soils.
The characterizations of grounding systems subjected to high impulse conditions are known to be dependent on the polarity, current to peak time and discharge time, as well as the electrical properties of the soil, and the grounding electrodes themselves. It is therefore important to investigate the behavior of grounding systems under high impulse conditions under negative impulse polarity, and compare it with positive impulse polarity results. Experimental test results for the same grounding systems installed with various earth electrodes at several sites under positive impulse polarity have previously been presented. In comparison, this paper presents the results of negative impulse polarity injected on the same grounding systems. It is found that a significant difference between positive and negative impulse polarities is observed for the grounding systems installed at high soil resistivity.
AC Servomotors are widely used in the industries for the control of static and dynamic loads. Precise control of position, speed, and torque are the main issues with the AC Servomotor. AC Servomotors are highly demanded by the industries to have a precise response under dynamic load conditions. Many control techniques are commercially available for the control of AC Servomotor under static and dynamic load conditions. However, all of these control techniques have advantages and limitations. Many investigations are done on the control of AC Servomotor, but comprehensive surveys on the control of AC Servomotor were still limited. In this paper, most of such commercially available control techniques are investigated, discussed, and compared.
This paper focuses on the simulation analysis of the conventional Internal Model Control (IMC) technique and the development of two proposed control techniques for the position control of AC Servo Motor. Internal Model Control (IMC) technique [1] was only able to control the AC Servo Motor under static load condition. Also, it had step response problems, and it was not robust against external disturbances. For these reasons, the IMC technique was further improved to control the AC Servo Motor under dynamic load conditions by proposing Amended Internal Model Controller (AIMC). The step response and the robustness of AIMC against external disturbances were further improved by proposing AIMC+FLC. Where a Fuzzy Logic Controller (FLC) is designed and connected with the AIMC.
This paper presents experimental results of high-current impulse tests on six ground electrode configurations. A high impulse current generator is employed to inject different magnitudes of current into these rod electrodes, under both positive and negative impulse polarities. The effect of increasing the number of rod electrodes, hence the resistance at DC or steady-state (RDC), on the impulse response of ground electrodes is analysed. From the analysis of the results, it was found that the larger the size of rod electrodes, the less current-dependent Zimpulse becomes. The percentage of reduction of impulse impedance, Zimpulse from its steady state, and RDC values are found to be independent of impulse polarity. However, as the voltage magnitudes were increased, an occurrence of breakdown was seen, with higher breakdown voltage seen in negative impulse polarity in comparison to positive impulse polarity. Relatively, the higher the breakdown voltage is, seen in the ground electrodes subjected to negative polarity, the faster the time to breakdown is.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.