2016
DOI: 10.1007/s00340-016-6617-3
|View full text |Cite
|
Sign up to set email alerts
|

Influence of laser energy on the electron temperature of a laser-induced Mg plasma

Abstract: radiations in this process are used for the identification of the elemental composition of the sample [7][8][9].LIBS offers many advantages over other spectroscopic techniques such as mass spectroscopy, electrode spark and inductively coupled plasma. Some of LIBS unique advantages include the ability to make in situ analysis even in hostile environment, remote sensing, little or no preparation of the sample, and multi-element analysis [10][11][12]. Based on these advantages, LIBS has been extensively investiga… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(9 citation statements)
references
References 31 publications
1
8
0
Order By: Relevance
“…Similar temperatures (in the order of 1E+4 K) have been commonly reported for orthogonal ablation with pulse energies ranging from 20 mJ to 200 mJ [34][35][36][37][38] , which validates our results. Overall, the observed temporal evolution of the temperature is in good agreement with existing reports [39][40][41][42][43] . In addition, for each plasma, the ionization fraction calculated according to (1,2) approached unity, which is in line with studies of orthogonal ablation 44 .…”
Section: Resultssupporting
confidence: 91%
“…Similar temperatures (in the order of 1E+4 K) have been commonly reported for orthogonal ablation with pulse energies ranging from 20 mJ to 200 mJ [34][35][36][37][38] , which validates our results. Overall, the observed temporal evolution of the temperature is in good agreement with existing reports [39][40][41][42][43] . In addition, for each plasma, the ionization fraction calculated according to (1,2) approached unity, which is in line with studies of orthogonal ablation 44 .…”
Section: Resultssupporting
confidence: 91%
“…The electron temperature was estimated from the Boltzmann and Saha-Boltzmann plot methods by utilizing the relative intensities of the emission lines of the Mg and Ti plasmas, respectively. The plasma obtained was optically thin, and the condition for local thermodynamic equilibrium to exist was warranted [44,45].…”
Section: Electron Temperaturementioning
confidence: 99%
“…The expression in Equation (2) can be condensed into the form of the Boltzmann's equation in Equation (1). Where E IP is the ionization energy, m is the mass of the electron, and the subscripts 1 and 2 denotes the neutral and ionic lines, respectively [44,[47][48][49][50].…”
Section: Electron Temperaturementioning
confidence: 99%
“…In the LIBS technique, the plasma emission spectra of the target sample are investigated. The plasma generated at the surface of the target, such as gas, liquid, and solid, is normally generated when the high-power laser beam is focused onto the target material [ 7 , 8 , 9 ]. The plasma emission spectrum from the laser-produced plasma gives the optical fingerprints of the sample ingredients [ 10 , 11 ].…”
Section: Introductionmentioning
confidence: 99%