A graphene oxide (GO)/poly 3-methyl aniline (P3MA) photodetector has been developed for light detection in a broad optical region: UV, Vis, and IR. The 3-methyl aniline was initially synthesized via radical polymerization using an acid medium, i.e., K2S2O8 oxidant. Consequently, the GO/P3MA composite was obtained through the adsorption of GO into the surface of P3MA. The chemical structure and optical properties of the prepared materials have been illustrated via XRD, FTIR, SEM, and TEM analysis. The absorbance measurements demonstrate good optical properties in the UV, Vis, and near-IR regions, although a decrease in the bandgap from 2.4 to 1.6 eV after the composite formation was located. The current density (Jph) varies between 0.29 and 0.68 mA·cm−2 (at 2.0 V) under dark and light, respectively. The photodetector has been tested using on/off chopped light at a low potential, in which the produced Jph values decrease from 0.14 to 0.04 µA·cm−2, respectively. The GO/P3MA photodetector exhibits excellent R (and D) values of 4 and 2.7 mA·W−1 (0.90 × 109 and 0.60 × 109 Jones) in the UV (340 nm) and IR (730 nm) regions, respectively. The R and D values obtained here make the prepared photodetector a promising candidate for future light detection instruments.
In this work, we report the results of the compositional analysis of an aluminum gallium arsenide (AlGaAs) sample using the calibration-free laser-induced breakdown spectroscopy (CF-LIBS) technique. The AlGaAs sample was doped with three various concentrations of gallium (Ga), arsenic (As), and aluminum (Al), as reported by the manufacturer, and the CF-LIBS technique was employed to identify the doping concentration. A pulsed Q-switched Nd: YAG laser capable of delivering 200 and 400 mJ energy at 532 and 1064 nm, respectively, was focused on the target sample for ablation, and the resulting emission spectra were captured using a LIBS 2000+ spectrometer covering the spectral range from 200 to 720 nm. The emission spectra of the AlGaAs sample yielded spectral lines of Ga, As, and Al. These lines were further used to calculate the plasma parameters, including electron temperature and electron number density. The Boltzmann plot method was used to calculate the electron temperature, and the average electron temperature was found to be 5744 ± 500 K. Furthermore, the electron number density was calculated from the Stark-broadened line profile method, and the average number density was calculated to be 6.5 × 1017 cm−3. It is further observed that the plasma parameters including electron temperature and electron number density have an increasing trend with laser irradiance and a decreasing trend along the plume length up to 2 mm. Finally, the elemental concentrations in terms of weight percentage using the CF-LIBS method were calculated to be Ga: 94%, Al: 4.77% and As: 1.23% for sample-1; Ga: 95.63%, Al: 1.15% and As: 3.22% for sample-2; and Ga: 97.32%, Al: 0.69% and As: 1.99% for sample-3. The certified concentrations were Ga: 95%, Al: 3% and As: 2% for sample-1; Ga: 96.05%, Al: 1% and As: 2.95% for sample-2; and Ga: 97.32%, Al: 0.69% and As: 1.99% for sample-3. The concentrations measured by CF-LIBS showed good agreement with the certified values reported by the manufacturer. These findings suggest that the CF-LIBS technique opens up an avenue for the industrial application of LIBS, where quantitative/qualitative analysis of the material is highly desirable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.