2020
DOI: 10.21037/qims-19-921
|View full text |Cite
|
Sign up to set email alerts
|

Influence of feature calculating parameters on the reproducibility of CT radiomic features: a thoracic phantom study

Abstract: Background: Existing studies have demonstrated that imaging parameters may affect radiomic features.However, the influence of feature calculating parameters has been overlooked. The purpose of this study is to investigate the influence of feature calculating parameters (gray-level range and bin size) on the reproducibility of CT radiomic features.Methods: Thirty-six CT scans from an anthropomorphic thoracic phantom were acquired with different imaging parameters including effective dose, pitch, slice thickness… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…Radiomics (1)(2)(3)(4)(5) holds great promises in clinical oncology to aid better diagnosis, prognosis, and personalized clinical decision making, as witnessed by a huge number of research studies published in recent years (6)(7)(8)(9)(10)(11)(12)(13). However, the broad validity and generality of radiomics are much hindered by the concerns on its reliability (14)(15)(16)(17)(18)(19)(20). Besides disease, tissue, and physiological characteristics in the patients, variability and uncertainty of radiomics can be introduced in many procedures of the complicated workflow.…”
Section: Introductionmentioning
confidence: 99%
“…Radiomics (1)(2)(3)(4)(5) holds great promises in clinical oncology to aid better diagnosis, prognosis, and personalized clinical decision making, as witnessed by a huge number of research studies published in recent years (6)(7)(8)(9)(10)(11)(12)(13). However, the broad validity and generality of radiomics are much hindered by the concerns on its reliability (14)(15)(16)(17)(18)(19)(20). Besides disease, tissue, and physiological characteristics in the patients, variability and uncertainty of radiomics can be introduced in many procedures of the complicated workflow.…”
Section: Introductionmentioning
confidence: 99%
“…Significant ICC values between 0.75 and 0.9 and greater than 0.9 were considered as indicating good and excellent reliability, respectively. To complement the evaluation of ICC, Coefficient of Variation was considered in order to evaluate within-lesion variations: imaging features with good to excellent ICC but with COV > 20% were considered not-reproducible [30].…”
Section: Discussionmentioning
confidence: 99%
“…Considering that the ICC calculation relies on the natural variance of the underlying data, testing repeatability alone may be insufficient. Kendall’s W ( 58 ) can also evaluate IOV consistency when three or more operators are present, i.e., test–retest analysis is a necessity to maximize the robustness of imaging attributes.…”
Section: Radiomicsmentioning
confidence: 99%