2020
DOI: 10.3390/en13205516
|View full text |Cite
|
Sign up to set email alerts
|

Influence of FACTS Device Implementation on Performance of Distribution Network with Integrated Renewable Energy Sources

Abstract: In the modern power system, Flexible Alternating Current Transmission System (FACTS) devices are widely used. An increased share of the distributed generation (DG) and the development of microgrids change the power flows in the existing distribution networks as well as a conventional power flow direction from the transmission to the distribution network level which may affect the overall stability aspects. The paper shows the FACTS devices’ implementation influence on the performance of the distribution networ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 31 publications
0
9
0
Order By: Relevance
“…Mathematically, the establishment process should be nonlinear differential equations, covering the entire process of establishment in general, the solutions of which should reflect the specified gradual decrease in speed and increase in amplitude. However, due to the lack of any general methods for integrating nonlinear differential equations, it is necessary to search for such approximate methods that, to some extent, reflect the physical picture of the processes under consideration [15][16][17][18].…”
Section: Establishment Processes In a Saturated Machinementioning
confidence: 99%
“…Mathematically, the establishment process should be nonlinear differential equations, covering the entire process of establishment in general, the solutions of which should reflect the specified gradual decrease in speed and increase in amplitude. However, due to the lack of any general methods for integrating nonlinear differential equations, it is necessary to search for such approximate methods that, to some extent, reflect the physical picture of the processes under consideration [15][16][17][18].…”
Section: Establishment Processes In a Saturated Machinementioning
confidence: 99%
“…However, it is possible to optimize the input or output of reactive power dispatch using D-FACTS. These systems can contribute to control voltage levels, as well as improve system reliability [27], [28]. So, it is necessary to define the maximum value of susceptance capacitive (which will be represent the injected reactive power to the grid), , and the minimum value of susceptance capacitive (which will be represent the absorbed reactive power from the grid), .…”
Section: Thementioning
confidence: 99%
“…Therefore, this criterion forces that the total expected load must be supplied, and it is weighted by coefficient. Adding this new criterion in (28), the criterion is written as:…”
mentioning
confidence: 99%
“…Similarly, TCSC is more reliable as compared to STAT-COM for long-distance transmission lines [25]. When SVCs are compared to STAT-COM, STAT-COM gives efficient results at a higher cost [26]. Furthermore, the effectiveness of SVC and TCSC to decrease real power losses and to improve voltage profile have been discussed in the literature [27,28].…”
Section: Introductionmentioning
confidence: 99%