2016
DOI: 10.3390/photonics3020022
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Ethanol on Breath Acetone Measurements Using an External Cavity Quantum Cascade Laser

Abstract: Broadly tunable external cavity quantum cascade lasers (EC-QCLs) in combination with off-axis integrated cavity enhanced spectroscopy (OA-ICOS) provide high molecular gas sensitivity and selectivity. We used an EC-QCL in the region of 1150-1300 cm´1 in both broadband scan mode, as well as narrow scanning mode around 1216 cm´1, respectively, for detection of acetone in exhaled breath. This wavelength region is essential for accurate determination of breath acetone due to the relative low spectral influence of o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
11
0
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 32 publications
1
11
0
2
Order By: Relevance
“…Note that all of these three spectroscopy options are available with the same setup without any physical change in the source or other parts of the spectrometer. In comparison to OA-ICOS with ~1000 m effective interaction length [ 15 , 38 ], we obtain a similar sensitivity with WMS-2f and a multipass cell. In addition, the measurement time of the current WMS-2f system is substantially faster than OA-ICOS system.…”
Section: Direct Absorption and Wavelength Modulation Spectroscopysupporting
confidence: 54%
See 2 more Smart Citations
“…Note that all of these three spectroscopy options are available with the same setup without any physical change in the source or other parts of the spectrometer. In comparison to OA-ICOS with ~1000 m effective interaction length [ 15 , 38 ], we obtain a similar sensitivity with WMS-2f and a multipass cell. In addition, the measurement time of the current WMS-2f system is substantially faster than OA-ICOS system.…”
Section: Direct Absorption and Wavelength Modulation Spectroscopysupporting
confidence: 54%
“…However, the cost of MS instruments is very high, they need sample preparation and do not offer portable operation. Laser spectroscopy provides an alternative to MS methods with lower cost, portable operation, compactness and ease of use; which has been already employed (e.g., QCLs or EC-QCLs based systems) for acetone detection in human breath or its stand-off detection [ 38 , 48 , 53 , 54 ]. Acetone has broadband absorption features in the mid-infrared region with a large amount of closely spaced ro-vibrational transitions.…”
Section: Direct Absorption and Wavelength Modulation Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…The performance of narrowband WMS detection is comparable to recent EC-QCL-based WMS setups [8,9,12] and close to cavity-enhanced spectrometers [10,13]. The sensitivity was ultimately limited by fluctuations in the wavelength-dependent background caused by fringes.…”
Section: Discussionmentioning
confidence: 66%
“…Such external-cavity QCLs (EC-QCLs) also offer a large (~100 cm −1 ) mode-hop-free tuning range and high-bandwidth fine tuning via piezoelectric elements and laser injection current [1,5]. Consequently, EC-QCLs have been used for highresolution broadband absorption spectroscopy [6,7], as well as for sensitive narrowband detection in environmental, combustion and medical applications [8][9][10][11][12][13]. Given the high output power, EC-QCLs are also well-suited for photo-acoustic spectroscopy [14].…”
Section: Introductionmentioning
confidence: 99%