Influence of Dispersed-Phase Viscosity on Droplet Breakup in a Continuous Pump-Mixer

Abstract: The influence of dispersed-phase viscosity on droplet breakup in a pump-mixer was determined using a direct measurement approach, which was performed using a high-speed online camera. The experimental results show that the interfacial stress and internal viscous stress can be applied to characterize the influence of the interfacial tension and dispersed-phase viscosity on drop breakup, respectively. The daughter droplet size presents a bell-shaped distribution and is slightly dependent on the drop restoring st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
41
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 17 publications
(45 citation statements)
references
References 44 publications
(85 reference statements)
4
41
0
Order By: Relevance
“…Multiple breakageIn this section, the probability distributions of the number of fragments, the maximum stable drop diameter, and the percentage of binary breakage were discussed.Figure 9shows the proportion of binary, ternary, quaternary, and quaternary+ breakage. Similar to our previous studies,45,46 the binary breakup is dominant over wholeF I G U R E 7 Experimental breakup time versus the predicted breakup time (a) based on Equation 9, c 5 = 210, (b) based on Equation (12) [Color figure can be viewed at wileyonlinelibrary.com]…”
supporting
confidence: 60%
See 2 more Smart Citations
“…Multiple breakageIn this section, the probability distributions of the number of fragments, the maximum stable drop diameter, and the percentage of binary breakage were discussed.Figure 9shows the proportion of binary, ternary, quaternary, and quaternary+ breakage. Similar to our previous studies,45,46 the binary breakup is dominant over wholeF I G U R E 7 Experimental breakup time versus the predicted breakup time (a) based on Equation 9, c 5 = 210, (b) based on Equation (12) [Color figure can be viewed at wileyonlinelibrary.com]…”
supporting
confidence: 60%
“…Ashar et al 36 Recently, experiments have been carried out by Li's group to directly measure the breakup rate in a pulsed column [38][39][40]44 and in a pump-mixer. 45,46 In the above study, the multiple breakup process is treated mathematically as a sequence of the binary breakup. In this study, experimental data of the breakup rate are also provided.…”
Section: Review Of Experimental Study On Drop Breakup Time and Breamentioning
confidence: 99%
See 1 more Smart Citation
“…the breakup time, and the number of fragments were recorded. The breakup rate was also measured using Equation 1, which is consistent with the method adpoted by our previous study 45 .…”
Section: Review Of Experimental Study On Drop Breakup Time and Breakup Ratesupporting
confidence: 80%
“…Recently, experiments have been carried out by Li's group to measure the breakup rate directly in a pulsed disc and doughnut column [38][39][40]44 and in a pump-mixer 41,45 . In the above study, the multiple breakup process is treated mathematically as a sequence of the binary breakup.…”
Section: Review Of Experimental Study On Drop Breakup Time and Breakup Ratementioning